Side view
Illustr. 21 Installation of corrugated metal pipe solar
return
– Realise piping of the fresh water station or use pi-
ping set item no. 138 35 80.
– Suspend controller into the solar group bracket.
– Lay controller cables inside the designated cable
channels (illustr. 22).
Cable channel
Illustr. 22 Installation of cable channel
– Mount front insulation shell of the fresh water sta-
– Mount front insulation shell of the solar group.
– Fix type plate of the storage cylinder on the right
Back view
Illustr. 23 Fixing of type plate
tion.
hand side of the solar station on the storage cylin-
der insulation (The type plate can be found between
the insulation and the cover of the storage cylin-
der ).
The complete pipework must be
insulated thoroughly to minimise
heat loss.
DANGER
Danger to life and damage to property through
operating error or incomplete installation
For this reason:
The following conditions are to be checked before
initial operation:
The ball valves of the solar station must be in
open position
A safety valve with diaphragm expansion tank
must be installed in the solar circuit.
Fix type
plate here
31