rapid accumulation of water due to storms, rough weather and/ or rapid leaks created by hull
damage and or unsafe navigational conditions.
With all applications, it is important that a system of safe working practice is applied to
installation, use and maintenance. In order to securely fasten the unit, ensure that the
mounting surface is a minimum thickness of 19mm (3/4") (when fitted with the screws
supplied).
NOTE Do not screw directly to the hull. This pump must be mounted on a bulkhead or on an
additional board.
WARNING: Fire hazard. Wiring must comply with applicable electrical standards and include
a properly rated fuse or circuit breaker. Improper wiring can cause a fire resulting in injury or
death. Switch off the power while making connections.
Suggested wiring information is given as a guide only. For full information, refer to the USCG, ABYC
and ISO regulations for marine applications and wiring gauges, connectors and fuse protection.

8. PARTS LIST

Qty 1 Orca Auto 1300 Pump
9. INSTALLATION
NOTE: Incorrect installation will invalidate warranty
Preparation - Always disconnect power sources before installation.
9.i Location
Choose a position to mount the pump that is dry and away from standing water and is free
from obstacles.
Mount in a position with the shortest possible pipe run lengths.
9.ii Mounting Instructions
To remove pump body, place hand over body, depress
locking tabs (eyes) and lift body from strainer base (Figure
1). NOTE: Motor will be removed with body
Use base as template to mark 3 mounting holes in
mounting pad.
Drill 1/8" (3mm) pilot holes. NOTE: do not drill through hull;
ensure that the Orca is mounted securely to additional
board or bulkhead.
Use 25mm (1") or 28mm (1 1/8") smooth bore reinforced
hose to connect to the strainer with hose clips.
Replace base. Attach with #8 stainless steel fasteners (supplied).
Re-attach pump body to base. Insert body into strainer base, until base tabs snap into holes.
9.iii Plumbing
IMPORTANT: To prevent airlock, hose must rise continually upward to the thru-hull
connector with no dips or sharp bends. Hose support clips should be used at regular
intervals where necessary.
Orientate the pump outlet for a direct path
to the hull connector ensuring an
unobstructed hose path.
Secure all connections with hose clamps.
If no thru-hull connector exists, install at
12" (25mm) minimum height above
water line. Apply marine sealant around
thru-hull flanges on interior and exterior
of hull.
Qty 1
Screw Kit
Figure 2 -
Mounting
Hose must rise upwards
with NO DIPS
instructions
Figure 1 -
Removing
base
Press
both
locking
tabs to
release
cover
Skin Fittings
Suitable Mounting Pad
Outlet 12"
(305mm)
minimum
above the
water line