Fasep 2000 srl
Balatron B140.G2.TC: User's Manual
4
CALIBRATION
G
NOTE:
the following symptoms indicate need for calibration:
a) check calibration program fails.
b) constant low or high weight readings.
c) indicated point of umbalance constantly wrong.
d) more than 2 spins required to balance wheels repeatedly.
4.1
How to calibrate the Wheel Balancer B140.G2.T, B140.G2.TC
Place a wheel on the flange as show on fig. 8.
Switch on the wheel balancer.
Press <SET> when SOF X.XX (software version) is
displayed. It will appear CAL on the left display.
Press <SET> to start the calibration program.
Hand spin the wheel
G
NOTE: ACC EL: impress greater speed.
RED UCE: reduce the speed.
GO OD: the speed is corrected.
Apply a 160g weight on the internal side of the wheel
(Fig. 9).
Hand spin the wheel
End of calibration.
Press <MODE/ESC> to return to normal balancing
mode.
F
F
4-1
. 8
IG
. 9
IG
Rev. 1.3
01 June 2013