6. The cabinet should be installed with a very slight
tilt (about 1/2") downward toward the outside
(See Fig. 5). Adjust the bolt and the nut of
Sill Support
for balancing the cabinet.
6
7. Attach the cabinet to the window stool by driving
the screws
[Type B: Length 16mm (5/8 inch)
2
and below.] through the front angle into window
stool.
(Fig. 5)
8. Pull each Frame Curtain to each window
sash track, and repeat step 2.
9. Attach each Frame Curtain
sash using screws
(Type C). ( Fig. 6)
3
CAUTION: Do not drill a hole in the bottom pan.
The unit is designed to operate with
approximately 1/2" of water in bottom
of pan.
There is no need to add water if the
pan is dry.
10. Slide the unit into the cabinet. ( Fig. 7)
CAUTION: For security purpose , reinstall the 2
screws (Type A) at cabinet's side, that
were removed in step 1 on page 12.
11. Cut the Foam-Strip
(window width) and wedge between the upper
window sash and the lower window sash.
( Fig. 8)
5
(Fig. 5)
to the window
5
to the proper length
Screw(Type B)
2
Screw(Type B)
Sill Support
6
Screw(Type A)
14
Sill Support
Sash track
Front Angle
2
Fig. 5
Type C
3
Fig. 6
Power cord
Screw(Type A)
1
Fig. 7
Foam-Strip
Fig. 8
6