19.5 Connecting the grounding electrode/grounding conductor
Connect the connection cable' s grounding conductor to the specified grounding point
(the ground terminal). If a grounding electrode has been installed, connect that to the
ground terminal as well, as shown in diagram 1.1. Perform the entire grounding process in
accordance with the guidelines currently in force, namely NEN1010/EU/35

19.6 Opening and locking the charging station

The lid with Euro profile cylinders can only be installed with the corresponding keys. By
default, 2 Euro profile cylinders are installed by Ecotap®.
One of these cylinders, for which no key is provided, is intended for Ecotap® technicians
only and should never be removed.
The keys for the temporarily installed 2nd Euro profile (on the right) are provided.
You are responsible for installing half a Euro profile cylinder if you wish to assign a key plan /
owner to this station.
To replace the cylinder, loosen the hexagon socket screw on the bottom of the cylinder for
which the key was provided. The cylinder can now be extracted through the back.
Placing the replacement cylinder in the same position and transferring the hexagon socket
screw allows the lock to be reinstalled.
In this "open" position, a slight lifting
movement allows the lid to be placed in the
lock opening of the fixed part.

20. MAINTENANCE

Always disconnect the charging station from its power supply completely
and read the manual before performing any maintenance or fixing any
malfunctions.
Repairs or replacements of components may only be done if using
products that are approved by the supplier. When in doubt, please contact
Ecotap® first.
Repairs and replacements must always be performed by an authorised person / specialist.
The maintenance must always comply with and be performed in compliance with NEN3140
and NEN50110 low voltage European standards.
Check the charging station for any leaks.
Test the heating element and the thermostat together to make sure they are working
25. www.ecotap.nl
Picture of a locked charging station.
14-04-22