Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
This mixer series-produced with EcoSmart
(flow limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 36)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Fault
Mixer stiff
Mixer dripping
Water escaping in area of swivel
spout
Water escaping at the threaded
base
Hot water temperature too low
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
- connection hoses not completely
screwed into basic body
- O-ring at the connection hose
defective.
- Hot water limiter incorrectly set
Assembly (see page 33)
English
Dimensions (see page 38)
Flow diagram (see page 38)
with EcoSmart
without EcoSmart
Spare parts (see page 40)
Cleaning (see page 39)
Operation (see page 37)
Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or after
a prolonged period of non-use.
Test certificate (see page 37)
®
65°C
®
®
Remedy
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter