(NOTE 1)
Indoor unit
Lighting
*60 (1,500)
60 (1,500)
or more
or more
from a wall
(NOTE 2)
80 (2,000) or more
160 (4,000) or more
Obstacles
Fig. 2
CAUTION
• Any vents, light fixtures, or other appliances which may
disturb the airflow might soil the ceiling if too close, so fol-
low Fig. 2 when installing.
Note)
1. This restriction applies to the exposed type lighting,
but does not apply to the recessed type, which does
not protrude below the ceiling line.
2. The clearance from the wall (indicated with *) must
be 20 in. (500 mm) or more if the air outlet is closed or
the horizontal blade is set to Airflow block and, if the
corners (left and right corners of the target air outlet)
are also closed by 8 in. (200 mm) or more.
For how to set the airflow direction (including Airflow
block) with the horizontal blade, refer to Individual
Airflow Direction in the operation manual attached
to the remote controller.
• Install the indoor and outdoor units, power supply wiring,
remote controller wiring and transmission wiring at least
40 in. (1 m) away from televisions or radios to prevent im-
age interference or noise.
(Depending on the radio waves, a distance of 40 in. (1 m)
may not be sufficient to eliminate the noise.)
• Install the indoor unit as far as possible from fluorescent
lamps.
If a wireless remote controller kit is installed, the transmis-
sion distance may be shorter in a room where an elec-
tronic lighting type (inverter or rapid start type) fluorescent
lamp is installed.
• Localized temperature difference from the room tempera-
ture, if too large, can affect how the infrared floor sensor
judges.
(This may occur, for example, in an area where floor
heating/high-temperature heat generating equipment is
installed.)
• Each sensor has been set so that the center of the sensing
area is located in the center of the product 32 in. (800 mm)
above the floor (in case of the infrared presence sensor)
or 0 in. (0 mm) above the floor (in case of the infrared floor
sensor) when the ceiling height is approximately 8-3/4 ft.
(2.7 m).
3P161684-7N
English
Exhaust
Indoor unit
fan
[unit: in. (mm)]
(2) Ceiling height
• This indoor unit can be installed in a space of which
ceiling height is up to 11-1/2 ft. (3.5 m) (Type 30 · 36 ·
48: 13-3/4 ft. (4.2 m))
• However, if the ceiling height exceeds 8-3/4 ft. (2.7 m)
(Type 30 · 36 · 48: 10-1/2 ft. (3.2 m)), it is necessary to
set from the remote controller on site. Refer to the sec-
tion 9. FIELD SETTING AND TEST OPERATION.
(3) Direction of the air discharge
• Select the number of directions of the optimum air
discharge for the shape or the position of the room.
• The number of directions of the air discharge can be
changed by installing a sealing material.
• When installing a sealing material, the field setting
from the remote controller is required. For details, refer
to the operation manual attached to the sealing materi-
als.
(It is set to the setting position number 01 (Standard ·
All round outlet) when shipped from the factory.)
• To use the optional sealing material kit to change the
setting of air discharge direction (4-way blow type (with
corners sealed)/3-way blow type), refer to the installa-
tion manual attached to it.
[Direction of air discharge]
*
All round
4-way
Fig. 3
(4) Use hanging bolts for installation.
Investigate if the installation place can withstand the
mass of the indoor unit and, if necessary, hang the indoor
unit with bolts after it is reinforced by beams etc.
(Refer to the installation pattern paper (5) for the mount-
ing pitch.)
(5) Infrared presence/floor sensor's sensing area
The sensing area is as shown in the figure below.
Infrared floor
sensor
Infrared
presence sensor
32 in. (800 mm)
Indoor unit installation
8-3/4 (2.7)
height h [ft. (m)]
Infrared presence sen-
Approx.
sor fa [ft. (m)]
28 (8.5)
Infrared floor sensor fb
Approx.
[ft. (m)]
36 (11)
*
*
*: Refrigerant
piping
3-way
[Target of detected area]
h
φa
φb
11-1/2 (3.5)
13 (4.0)
Approx.
Approx.
37-1/2 (11.5)
44-1/2 (13.5)
Approx.
Approx.
46 (14)
52-1/2 (16)
4