LGB Ge 4/4 II RhB Serie Mode D'emploi page 15

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
Register Assignment
1
Address
2
Minimum speed
3
Acceleration delay
4
Braking delay
5
Maximum speed
8
Reset
13
Function F1 – F8 with alternative track signal
14
Function FL, F9 – F15 with alternative track signal
17
Expanded address, higher value byte
18
Expanded address, lower value byte
19
Multiple unit operation address
21
Functions F1 – F8 with multiple unit operation
22
Function FL, F9 – F15 with multiple unit operation
Bit 4: Braking mode voltage against the direction of travel
27
Bit 5: Braking mode voltage with the direction of travel
Bit 0: Direction normal/inverted
Bit 1: Number of speed levels 14/28(128)
29
Bit 2: Analog operation off/on
Bit 5: short / long address active
Alternative Formats
50
Bit 1: Analog DC
Bit 3: mfx off/on
53
Motor control – control reference
54
Motor control – control parameter K
55
Motor control – control parameter I
56
Motor control – control influence
57
steam chuff 1
58
steam chuff 2
Range
Default
Register Assignment
1 – 127
3
0 – 255
20
60
0 – 255
5
0 – 255
5
63
0 – 255
255
64
8
131
67 – 94 Speed table for speed levels 1 – 28
0 – 255
96
112
0 – 255
1
113
192 – 231
192
114
0 – 255
128
115 – 135
0 – 255
0
137
0 – 255
0
138
0 – 255
0
0/16
139
16
0/32
140
0/1
0/2
141
6
0/4
142
0/32
143
0/2
10
144
0/8
145
0 – 255
245
146
0 – 255
16
148
0 – 255
32
149
0 – 255
42
176
0 – 255
1
177
0 – 255
0
14
Multi-station announcement
Bit 0 – 3: Number of stations
Bit 4: Last announcement changes the sequence
Bit 5: Locomotive direction changes the sequence
Bit 6: Start for the sequence
Total volume
Threshhold for squealing brakes
Mapping lights in the front, mode
Mapping lights in the front, dimmer
Mapping lights in the front, cycle
Mapping phys. outputs, lights in the rear, Aux 1 – 6,
compare 112 – 114
Factor for switching range
Volume for squealing brakes
Volume for Operating sounds
Volume for whistle blast
Volume for whistle blast
Volume for vacuum pump
Volume for Blower
Volume for sanding
Volume for Heating voltage relay
Volume for Greeting announcement
Volume for Greeting announcement
Volume for Station announcements
Minimum speed in analog DC
Maximum speed in analog DC
Range
Default
0 – 15
0/16
40
0/32
0/64
0 – 255
255
0 – 255
55
0 – 255
0 – 16
1
0 – 255
255
0 – 255
20
0 – 16
0 – 255
1 – 128
128
0 – 255
255
0 – 255
255
0 – 255
255
0 – 255
255
0 – 255
255
0 – 255
255
0 – 255
255
0 – 255
255
0 – 255
255
0 – 255
255
0 – 255
255
0 – 255
80
0 – 255
245