MAINTENANCE
NOTICE: Use only good quality hydraulic jack oil. Avoid mixing different types of fluid and NEVER use brake fluid,
turbine oil, transmission fluid, motor oil or glycerin. Improper fluid can cause premature failure of the jack and the
potential for sudden and immediate loss of load. Premium hydraulic jack oil is recommended.
Adding oil
1. With Ram Plunger fully lowered and pump piston fully depressed, set jack in its upright, level position. Remove
Oil Filler Plug/Screw.
2. Fill with oil until just below the rim of the oil filler hole. Reinstall the Oil Filler Plug/Screw.
Changing oil
For best performance and longest life, replace the complete fluid supply at least once per year.
1. With Ram Plunger fully lowered and pump piston fully depressed, remove the Oil Filler Plug/Screw.
2. Lay the jack on its side and drain the fluid into a suitable container.
NOTICE: Dispose of hydraulic oil in accordance with local environmental regulations.
3. Fill with oil until just below the rim of oil filler hole. Reinstall the Oil Filler Plug/Screw.

Lubrication

A periodic coating of light lubricating oil to pivot points, axles and hinges will help to prevent rust and assure that
pump assemblies move freely.
Cleaning
Periodically check the pump piston and Ram Plunger for signs of rust or corrosion. Clean as needed and wipe with
an oily cloth.
NOTICE: Do not use sandpaper or abrasive material on ram and pump piston surfaces.
Storage
When not in use, store the jack with pump piston and Ram Plunger fully retracted and air supply disconnected.
TROUBLESHOOTING
Symptom
Jack will not lift load
Jack will lift, but not maintain
pressure
Jack will not lower after
unloading
Poor lift performance
Will not lift to full extension
Possible Causes
• Release Valve not tightly closed
• Overload condition
• Release Valve not tightly closed
• Hydraulic unit malfunction
• Reservoir overfilled
• Fluid level low
• Air trapped in system
• Fluid level low
4

Corrective Action

• Ensure Release Valve tightly
closed
• Remedy overload condition
• Ensure Release Valve tightly
closed
• Contact Omega Tech. Service
• Ensure load is removed, then
drain fluid to proper level
• Ensure proper fluid level
• Follow Bleeding/Venting Trapped
Air procedure on page 3
• Ensure proper fluid level