GoodHome Duala Manuel D'utilisation page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

. .
. .
Installation
. .
. .
. .
.
Electrical connection
Warning: you need to connect the two
conductors of the supply cable to a
connection block in respecting the
polarities as following :
IMPORTANT: The wires in the mains
lead are coloured in accordance with
the following code :
Blue – Neutral
Brown – Live
The blue wire must be connected to the terminal
marked with an N or coloured black.
The brown wire must be connected to the
terminal marked with an L or coloured red.
WARNING: Never connect live or
neutral wires to the earth terminal.
This product is double insulated and must not be
earthed. If there are any incoming earth cables,
they must be joined together using a suitable
connector (not supplied) and well insulated with
good quality insulation tape. This is to ensure
earth continuity throughout your property.
Flex outlet method - metal frontplates
Connect the cables as shown in the diagram:
From supply:
Neutral
Live
Earth
ALL EARTH WIRES MUST BE SLEEVED AND
TERMINATED TO BACK BOX.
L
N
E
L
N
To appliance: Live
Neutral
DO NOT wire/fit a plug to this appliance. The
appliance must be electrically connected to a
fused fixed spur, which is fitted with a 10 Amp
fuse.
All fittings must be installed by a competent
person in accordance with the current IET
Wiring Regulations (BS7671). If in doubt, consult
a qualified electrician.
This product is suitable for use in living areas,
and Bathroom (dry) outside Zones and zone
2 only (see diagram below and current IET
Wiring Regulations for details). It is not suitable
for Bathroom Zones 0 and 1. If being fitted in
a bathroom a 30 mA RCD must be used. This
appliance does not come fitted/supplied with a
fused plug.
Always refer to the Reference Drawing for
Bathroom Installation.
Note: The below drawing is for reference only.
(DRY) OUTSIDE ZONES
ZONES 1
2.25 m
ZONES 0
IP24: THIS PRODUCT IS SUITABLE FOR
BATHROOMS (DRY) OUTSIDE ZONES AND
ZONE 2.
E
Full details can be found in the current IET
Wiring Regulations (BS7671).
Ceiling
ZONES 2
0.6 m
0.6 m
ZONES 2
10
Window
recess