resideo VR8215S Notice D'installation

resideo VR8215S Notice D'installation

Régulateurs à gaz à allumage direct à un étage

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

VR8215S,M,T Single Stage
Direct Ignition Gas Controls
APPLICATION
The VR8215S,M,T Single Stage Direct Ignition Gas
Controls are used in gas-fired appliances with up to
3
150 ft
/hr capacity at 1 in. wc pressure drop on natural
gas. They have been optimized for direct ignition
applications and include a on/off switch and a pressure
regulator.
SPECIFICATIONS
Size
Inlet x Outlet
Model
(in. NPT)
VR8215
1/2 x 1/2
a
Capacity based on 1000 Btu/ft
b
Minimum regulation for LP gas is 30,000 Btu/h (0.85 m
Table 2. Gas Capacity Conversion Factor.
Gas
Specific Gravity
Manufactured
Mixed
Propane
Options:
3/16 in. (4.8 mm) and 1/4 in. (6.4 mm) male quick-
connect ground terminals.
Barbed vent fittings for seated combustion:
Single stage: 1/8 in. (3.2 mm) and 1/4 in. (6.4 mm)
Body Pattern: Straight through; see Table 1 for inlet and
outlet size.
Electrical Ratings:
Voltage and Frequency: 24 Vac, 50/60 Hz.
Current Draw:
Single Stage: 0.5 A.
Field Wiring:
Single Stage: Two 1/4 in. spade quick-connect terminals.
Capacity: See Table 1.
Model Number Suffix Letter
S, M, T
Table 1. Valve Capacity.
AGA Certified Capacity for Natural
Gas
3
ft
/hr
150
3
, 0.64 sp gr natural gas at 1 in. wc pressure drop (37.3 MJ/m
3
/hr).
Multiply Listed
Capacity By
0.60
0.516
0.70
0.765
1.53
1.62
Table 4. Natural-LP Gas Conversion Kits.
Kit to Convert Natural Gas to LP
• Valve capacities are shown in Table 1.
• Table 2 provides gas capacity conversion factors.
• For suffix letter designation, see Table 3.
• VR8215M valves are designed for agricultural
applications.
a
AGA Certified Minimum
Regulation for Natural Gas
3
3
m
/hr
ft
/hr
4.25
b
15
Table 3. Model Number Suffix Letter Designation.
Regulation
Single Stage
Conversion:
Use conversion factors in Table 2 to convert capacities
for other gases.
Regulation Range: See Table 6.
Natural-LP Gas Conversion Kits: See Table 4.
Approvals:
CSA Design Certificate #112395.
(-40 °F to +175 °F; -40 °C to +79 °C)
Australian Gas Association Certificate #7960.
(single stage only) (-20 °C to +79 °C only)
Outlet: Class 2, Grade 20 pressure regulator
Auto shutoff valve function: Class 3
396221
INSTALLATION INSTRUCTIONS
AGA Certified
Maximum Regulation
for Natural Gas
3
3
m
/hr
ft
/hr
0.42
200
3
, 0.64 sp gr natural gas at 0.25 kPa pressure drop).
Model Number
Suffix Letter
S, M
T
Kit to Convert LP to Natural Gas
396222
3
m
/hr
5.66
Pressure Regulator
Type
Standard
Slow Opening
69-2253EF-01

Publicité

Table des Matières
loading

Sommaire des Matières pour resideo VR8215S

  • Page 1 VR8215S,M,T Single Stage Direct Ignition Gas Controls INSTALLATION INSTRUCTIONS APPLICATION The VR8215S,M,T Single Stage Direct Ignition Gas • Valve capacities are shown in Table 1. Controls are used in gas-fired appliances with up to • Table 2 provides gas capacity conversion factors.
  • Page 2: Planning The Installation

    VR8215S,M,T SINGLE STAGE DIRECT IGNITION GAS CONTROLS PLANNING THE INSTALLATION Heat Excessively high temperatures can damage the control. Make sure the maximum ambient temperature at the WARNING control does not exceed the rating of the control. If the appliance operates at very high temperatures, use Fire or Explosion Hazard.
  • Page 3 VR8215S,M,T SINGLE STAGE DIRECT IGNITION GAS CONTROLS 3. Thread the pipe the amount shown in Table 5 for Bushings insertion into control or adapters. Do not thread pipe too far. Valve distortion or malfunction can 1. Remove the seal over the control inlet or outlet.
  • Page 4 VR8215S,M,T SINGLE STAGE DIRECT IGNITION GAS CONTROLS 3. For single stage controls (VR8215S,M,T): adjust thermostat heat anticipator to 0.50A rating stamped on valve label. (HOT) S87B CONTROL MODULE ALARM, IF USED 24V (GND) ALARM VALVE VALVE DUAL VALVE COMBINATION GAS CONTROL...
  • Page 5: On/Off Switch

    VR8215S,M,T SINGLE STAGE DIRECT IGNITION GAS CONTROLS STARTUP AND CHECKOUT Check and Adjust Gas Input and Burner Ignition On-Off Switch Important 1. Do not exceed input rating stamped on The on-off switch settings are as follows: appliance nameplate, or manufacturer’s •...
  • Page 6 VR8215S,M,T SINGLE STAGE DIRECT IGNITION GAS CONTROLS NOTE: When using the VR8215T, the specified Check Safety Lockout ignition control safety lockout time must Slow-Opening (T) Controls Only exceed 8.5 seconds for the system to function properly. 1. With the system power off and the thermostat set to call for heat, manually shut off the gas supply.
  • Page 7 VR8215S,M,T SINGLE STAGE DIRECT IGNITION GAS CONTROLS 3. Remove the pressure regulator adjusting screw. SERVICE See Fig. 6. 4. Remove the existing spring. 5. Insert the replacement spring. See Fig. 6. WARNING 6. Install the new plastic pressure regulator adjust- ment screw.
  • Page 8: Turning Off The Appliance

    69-2253EF—01 M.S. Rev. 06-20 | Printed in United States www.resideo.com © 2020 Resideo Technologies, Inc. All rights reserved. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées.
  • Page 9: Régulateurs À Gaz À Allumage Direct À Un Étage Vr8215S,M,T

    Les régulateurs à gaz à allumage direct à un étage • Les capacités de la vanne sont illustrées dans le VR8215S,M,T sont utilisés dans les appareils à gaz d’une Tableau 1. capacité de 150 pi /h maximum avec chute de pression de •...
  • Page 10: Planification De L'installation

    RÉGULATEURS À GAZ À ALLUMAGE DIRECT À UN ÉTAGE VR8215S,M,T PLANIFICATION DE Accumulation de poussière ou de graisse L’INSTALLATION Des accumulations importantes de poussière ou de graisse peuvent entraîner le dysfonctionnement du régulateur. AVERTISSEMENT Lorsque de la poussière ou de la graisse peuvent poser problème, couvrez le régulateur pour limiter la...
  • Page 11: Installation Des Douilles Sur Le Régulateur

    RÉGULATEURS À GAZ À ALLUMAGE DIRECT À UN ÉTAGE VR8215S,M,T Suivez les instructions du fabricant de l’appareil le cas Utilisez un tuyau neuf correctement alésé et exempt échéant; sinon, référez-vous aux présentes instructions. d’écailles. Si des tubes sont utilisés, assurez-vous que les extrémités sont bien coupées à...
  • Page 12 RÉGULATEURS À GAZ À ALLUMAGE DIRECT À UN ÉTAGE VR8215S,M,T Vérifiez la tension électrique du régulateur et assurez- vous qu’elle correspond à l’alimentation disponible. COLONNE Installez un transformateur ou d’autres dispositifs si DESCENDANTE ALIMENTATION nécessaire. RÉGULATEUR HORIZONTAL EN GAZ (TUYAU) DE GAZ Branchez le circuit du régulateur aux bornes du régu-...
  • Page 13: Interrupteur Marche/Arrêt

    RÉGULATEURS À GAZ À ALLUMAGE DIRECT À UN ÉTAGE VR8215S,M,T MISE EN SERVICE ET Vérification et réglage de l’entrée de gaz et de l’allumage du brûleur VÉRIFICATION Important 1. Ne dépassez pas la valeur nominale de l’entrée Interrupteur marche-arrêt estampillée sur la plaque signalétique de l’appareil ou la pression de l’orifice du brûleur...
  • Page 14: Vérification Du Verrouillage De Sécurité Sur Régulateurs À Ouverture Lente (T) Uniquement

    RÉGULATEURS À GAZ À ALLUMAGE DIRECT À UN ÉTAGE VR8215S,M,T REMARQUE : Lors de l’utilisation du VR8215T, la Vérification du verrouillage de durée de verrouillage de sécurité du régulateur d’allumage spécifiée doit sécurité sur régulateurs à ouverture dépasser 8,5 secondes pour que le lente (T) uniquement système fonctionne de façon...
  • Page 15: Si Le Brûleur Principal Ne S'allume Pas Avec L'appel De Chaleur

    RÉGULATEURS À GAZ À ALLUMAGE DIRECT À UN ÉTAGE VR8215S,M,T Insérez le ressort de remplacement. Reportez-vous à MISE EN GARDE la Fig. 6. Installez la nouvelle vis de réglage du régulateur de Risque de dégât matériel. pression en plastique. Les thermostats ou d’autres organes peuvent être Vérifiez les paramètres du régulateur à...
  • Page 16: Instructions Destinées Au Propriétaire De La Résidence

    69-2253EF—01 M.S. Rev. 06-20 | Imprimé aux États-Unis www.resideo.com © 2020 Resideo Technologies, Inc. All rights reserved. This product is manufactured by Resideo Technologies, Inc. and its affiliates. Tous droits réservés. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées.

Ce manuel est également adapté pour:

Vr8215mVr8215t