Failure Display And Inspection - EAS ELECTRIC EMIH290-FX Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Pans do not become hot
and appears in the
display.
The induction hob or a
cooking zone has turned
itself off
unexpectedly, a tone
sounds and an error
code is displayed
(typically alternating
with one or two digits in
the cooking timer
display).

8. Failure Display and Inspection

The induction hob is equipped with a self diagnostic function. With this test the technician is able to check
the function of several components without disassembling or dismounting the hob from the working
surface.
Troubleshooting
1) Failure code occur during customer using & Solution;
Failure code
E1
Supply voltage is above the rated voltage.
E2
Supply voltage is below the rated voltage.
High temperature of ceramic plate sensor .
E3
1#
High temperature of ceramic plate sensor .
E4
2#
E5
High temperature of IGBT . 1#
High temperature of IGBT. 2#
E6
Ceramic plate temperature sensor failure-
F3/F6
-short circuit. (F3 for 1#,F6 for2#)
Ceramic plate temperature sensor
F4/F7
failure--open circuit. (F4 for 1#,F7 for2#)
F5/F8
Ceramic plate temperature sensor
The induction hob cannot
detect the pan because it is not
suitable for induction cooking.
The induction hob cannot detect
the pan because it is too small for
the cooking zone or not properly
centred on it.
Technical fault.
Problem
Auto-Recovery
No Auto-Recovery
Use cookware suitable for induction
cooking. See section 'Choosing the right
cookware'.
Centre the pan and make sure that its
base matches the size of the cooking
zone.
Please note down the error
letters and numbers, switch
the power to the induction hob
off at the wall, and contact a
qualified technician.
Please inspect whether power supply is
normal.
Power on after the power supply is normal.
Wait for the temperature of ceramic plate
return to normal.
Touch "ON/OFF" button to restart unit.
Wait for the temperature of IGBT return to
normal.
Touch "ON/OFF" button to restart unit.
Check whether the fan runs smoothly;
if not , replace the fan.
Check the connection or replace the
ceramic plate temperature sensor.
21
Solution
V.2

Publicité

Table des Matières
loading

Table des Matières