and select a value between 0...9
⇑
with the right key.
3.3 General Information about Programming
Note
When this manual instructs to press
both keys simultaneously, press the
⇑
⇑
left key slightly before the right key.
4. Programming
4.1 Call for the Programming Mode
To call the programming mode:
1. Press simultaneously both front side keys and hold
them pressed for at least 3 seconds.
⇑
⇑
2. The following message is displayed
3. In addition, a blinking request for confirmation is
displayed. Press the right key to switch over bet-
ween YES and No
⇑
4. If YES is displayed and both keys are pressed, the
programming mode is called for. no exits the pro-
gramming mode
⇑
⇑
4.2 Programming Mode
1. Press the right key and select the operating mode:
⇑
2. 3 operating modes are available:
3. After selecting the operating mode, press both
keys. Programming can start now.
⇑
⇑
The three operating modes can be programmed
independently of each other.
4.2.1 The SEtP Operating Mode
1. The following parameters can be programmed for
the SEtP mode:
⇑
⇑
–
SiGnal allows selecting the setpoint output in volts
or mA. Press both keys to switch over from SiGn to
ou.Lo and ou.HI.
–
output.Low allows defining the lowest value.
–
output.High allows defining the highest value.
During operation, it is not possible to define a value
lower than the ou.Lo value or higher than the ou.Hi
value. The default value for ou.Lo is 0 V or 0 mA. The
default value for ou.Hi is 12 V or 24 mA.
2. After setting the value of ou.Hi, press both keys;
the following message is displayed:
3. Use the right key to select YES or no.
⇑
⇑
to
for mA 24.00
to
for mA 24.00
EN - Page 4