Inputs:
2 front side keys for setting and pro-
gramming
Hold input: optocoupler, high active
low: 0...2 VDC / high: 4...30 VDC
Outputs:
Current output 0...24 mA,
increment 10 µA
Load uu to 20 mA: ≤ 500 Ohms,
> 20 mA: ≤ 400 Ohms
Ripple: <10 mVpp
Voltage output 0...12 V,
increment 10 mV,
Load ≥ 2 kOhms, Ripple: <10 mVpp
Accuracy:
< 0.2 % of the final value
Temperature drift: < 200 ppm/K
6. Connecting Diagram
1.1 1.2 1.3 1.4 1.5 1.6 1.7
Inputs
1.1: PWR+ (10...30 V DC)
1.2: PWR- (GND)
1.3: PWR- (GND)
1.4: HOLD
Outputs
1.5: I OUT+ (0...24mA)
1.6: PWR- OUT (GND, OUT)
1.7: U OUT+ (0...12V)
Screw terminals RM5.08:
0.14...1.5 mm
2
, 26...16 AWG
Block diagram and connection see
point 1.4
7. Scope of Delivery
1 Digital display
1 Panel mounting clip
1 Bezel for clip mounting,
panel cut-out 50 x 25 mm
1 Bezel for screw mounting,
panel cut-out 50 x 25 mm
1 Gasket
1 Multilingual operating manual
EN - Page 9
ambient
8. Order Information
Setpoint generator
CODIX 533: 6.533.012.300
9. Error Messages
Err0: Programming error, e.g.: the value input is
above ou.Hi
10. Dimensions, see folding pages