2. Functions
–
SPecial display function, see 4.2.3.1
–
SiGnal allows selecting the setpoint output in volts
or mA.
–
time allows selecting the time unit in seconds or
minutes.
–
Number of PEriods allows defining the number of
reference points.
–
output 1 allows selecting the current or voltage
value for the first reference point.
–
PEriod. 1 allows defining the duration of the first
period (a maximum of 20 periods may be pro-
grammed). The maximum setpoints ou. X and the
times PE. X result from the setting of PEr.
–
The function cYcle allows defining the number of
cycles to be carried out.
If cYcle = 0,
is displayed automatically after 1 second. noCYcle
will start an endless loop.
Press both keys simultaneously to switch over to the
following parameter. Within a parameter, select the
decade with the left key and select a value from
0...9 with the right key.
3. After setting the value of cYcl, press both keys
simultaneously; the following message is displayed:
4. Use the right key to select YES or no
⇑
5. If YES is selected, press both keys simultaneously
to end the programming
⇑
⇑
6. The device is now ready for
operation. Press the right key to start it and the left
key to stop it.
EN - Page 7
Note:
After powering, the device outputs 0.00 mA or 0.00 V.
The Auto function does not start automatically.
Alter the manual start of the Auto function, the device
outputs the value ou.1. After the execution of the
cycle, the output remains with the value ou.1.
4.2.3.1 The
Auto Operating Mode
1. If YES was selected for
can show a value different from the value of the
output setpoint.
2.The SPecial disPlay function
–
The function SPecial.decimalPoint allows defining
the number of decimal places (only for the values
appearing on the display).
–
display.Low allows defining the minimum value to
be displayed.
–
display.High allows defining the maximum value to
be displayed.
A
SPecial disPlay Function in
A
, the display
to
bei mA 24.00
to
bei mA 24.00
to
to
to
A
to
bei mA 24.
to
bei mA 24.
to