Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.
Conversion to different types of gas
Before carrying out any maintenance work, disconnect the appliance from the gas and electric
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described
in fig. 5.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 8) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE A: Adapting to different types of gas
Burner
Semi-Rapid
Rapid
Inner
Dual
burner
Outer
CAUTION: save the orifices removed from the appliance for future use

Regulation of burners

Regulation of the "MINIMUM" on the burners
To regulate the minimum on the burners carry out the following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2) Remove the knob ( Fig. 9) of the tap which is set for standard pressure. The knob is found on the bar of
the tap itself.
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower
part of the tap and turn the fixing screw to the right or left until the flame of the burner is regulated in the most
suitable way to MINIMUM.
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the
MINIMUM position.
ATTENTION: The regulation described above can be carried out only with burners using natural gas,
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.
Adaptation of the pressure regulator for use with different type of gas
The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with
Natural Gas at a nominal outlet pressure of 4" w.c. or LP gas at a nominal outlet pressure of 11" w.c. and it is
pre-arranged from the factory to operate with one of these gas/pressure as indicated in the pre-arranging
labels affixed on the appliance, package and Instruction booklet.
To convert the regulator for use with the other gas different from which one it is pre-arranged it is enough
perform the following operations:
1) Unscrew by hand the upper metal stopper of the regulator (Fig. 5).
2) Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper, afterward
screw it again in opposite way under the metal stopper (for gas reference see the written "LP" and "NAT" with
relative indicating arrows on the white piece).
3) Screw again by hand the metal stopper in the original position on the regulator.
Operating in this way the gas regulator is converted for use with the other gas/pressure.
Inj. size
Gas
1/100mm
Type
117
NG
73
LP(Propane)
155
NG
98
LP(Propane)
80
NG
50
LP(Propane)
N°2 x 130
NG
N°2 x 83
LP(Propane)
Pressure
Max Rate
[i.w.c.]
[BTU/h]
4"
6000
11"
6300
4"
10400
11"
11400
4"
2730
11"
2900
4"
15000
11"
16400
7
Min Rate
[W]
[BTU/h]
[W]
1759
1500
439
1845
1500
439
3046
2500
732
3339
2500
732
799
900
264
849
900
264
4394
4500
1318
4804
4500
1318
By-pass size
[1/100mm]
Regulated
36
Regulated
47
Regulated
29
Regulated
65