IN THE BOX
a. Inline Pressure Boosting System
b. Installation Manual
c. Pressure Tank (accessory if ordered & included with Inline 400)
All Franklin Electric Inline Pressure Boosting Systems are carefully tested, inspected, and packaged to ensure their arrival in perfect condition. When the
unit is received, examine it closely to make sure there is no damage that may have occurred in shipping.
If damage is evident, report this immediately to your shipping carrier and product dealer. The shipping carrier assumes full responsibility for the
shipment's safe arrival. Any claim for damage to the shipment, either visible or concealed, must be made through the shipping carrier first.
STATUS DISPLAY
The Inline 400 product line is designed to provide basic feedback regarding the systems current operational state. This communication is transmitted
via the products LED light, integrated into the control head module. The LED can be seen flashing in a repetitive pattern representing operational state.
If the Inline 400 has detected a fault condition, the repetitive flashes can be counted to determine which fault the unit is reporting as the cause. The
Troubleshooting Guide provides more information on the possible faults being reported via LED light flashes.
Solid Green
Indicates system is powered and is turned ON, but not currently running. The green solid light will only be present when no faults are active.
Flashing Green
Indicates the pump is powered, turned ON, and running. A rapid blinking green light (two blinks per second, followed by one second off) indicates inlet
water supply pressure is above 40 PSI. The unit remains on stand-by until the inlet pressure switch detects incoming water pressure below the 40 PSI limit.
Solid Red
Indicates the control is powered but currently in the OFF mode. Pressing the button will toggle the unit into the ON mode.
Flashing Red
Indicates a FAULT has occurred. The unit will automatically attempt to restart. If an immediate restart is needed, the button can be pressed to force a
reset if the fault is no longer present. If the problem persists, a qualified water professional should be contacted. See Troubleshooting Guide for further
detail on various fault code LED flash indications.
Button
The button can be used to turn the unit on or off. When the unit is powered but in the OFF mode (solid red light), a press of the button will turn the
unit ON. If the unit is powered and in the ON mode (solid green light), a press of the button will shut the unit OFF. The button can also be used to force
a reset after a fault.
6