TROUBLESHOOTING
Problem
Possible cause
The power adaptor is not
supplied with voltage.
The blue power LED does
not light up.
The power adaptor is
overloaded.

CLEANING AND CARE

Do not use any aggressive cleaning agents, rubbing alcohol or other chemical
solutions as they can cause damage to the housing and malfunctioning.
• Before cleaning, disconnect the product from the power supply and from all connected
devices.
• Never submerge the product in water.
• Maintenance or repairs may be carried out by qualified professionals only.There are no
components located inside the product you need to maintain. Never open/dismantle the
product.
• To clean the product, a dry, soft and clean cloth is sufficient. Do not apply too much
pressure to the housing to prevent scratching.
• Use a longhaired, soft and clean brush and a vacuum cleaner to easily remove dust.
DISPOSAL
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the relevant
statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.

TECHNICAL DATA

Operating voltage .......................... 100 – 240 V/AC, 50/60 Hz
Output voltage / current ................. 19 V/DC, 6.3 A ±10 % (DC output cable)*
.......................................................
19 V/DC, 5.7 A ±10 % (DC output cable)**
.......................................................
5 V/DC, 2.1 A (USB)
Output power ................................. max. 120 W* / max. 118 W**
Cable length .................................. 1.2 m (power cable) / 1.5 m (DC output cable)
Operating conditions ...................... 0 to +35 ºC, 10 – 85 % RH
Storage conditions ......................... -10 to +55 ºC, 5 – 95 % RH
Dimensions (W x H x D) ................ 122 x 19 x 75 mm
Weight ........................................... approx. 320 g (without power cable/accessories)
*if a notebook and no USB device is connected
**if a notebook and a USB device are connected
Solution
Check the power outlet's
circuit breaker.
Check whether the power
adaptor is correctly
connected to the power
outlet.
Disconnect all devices from
the power adaptor and
check all technical data.
These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 96 04 / 40 87 80
(www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2013 by Voltcraft®
Plug
Label
E
G
N
P
Q
T
X
Z
Legal notice
Plug Ø
Suitable for
inner / outer
1.4 / 6.5 mm
Sony
1.0 / 5.0 mm
Samsung
0.9 / 7.9 mm
IBM
Acer, Compaq,
2.5 / 5.5 mm
Dell, HP, Fujitsu,
Gateway, Toshiba
0.6 / 7.4 mm
HP, Compaq
1.7 / 4.75 mm
HP, Compaq
1.7 / 5.5 mm
Acer
0.6 / 7.4 mm
Dell

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

40 97 41

Table des Matières