BATTERY CHARGER AND COMPONENTS
LED INDICATORS:
Red (Fault):
Blinking: Battery not able to charge Solid: Reverse polarity hook-up
Blue (STANDBY): AC power connected
5 Red LEDs:
Blinking: Connection correct and charging
Solid: Fully charged
OPERATING INSTRUCTIONS
IMPORTANT: ALWAYS disconnect the AC power cord from AC power outlet
before connecting (or disconnecting) the charger to (or from) the battery.
Connecting the Charger and Charging the Battery with Battery Clamps
The charger's output leads have color-coded battery clamps (RED-POSITIVE
and BLACK-NEGATIVE).
1. Unplug the battery charger AC cord from the AC outlet.
2. Disconnect the battery clamps from the unit at output and cord connector.
3. Connect the RED POSITIVRE clamp to the POSITIVE post of the battery.
4. Connect the BLACK NEGATIVE clamp to the NEGATIVE post of the battery.
5. Press the voltage button to proper setting and plug the AC cord into the AC
outlet.
6. Observe the blue LED that indicates the unit is operating, RED status LED
brings indicates the unit is charging for battery.
7. Leave the unit on.
8. Monitor the battery from time to time.