EN
Filling
(for small quantities)
1a.
2a.
3a.
4.
5.
1b.
2b.
3b.
Filling with grease
1a.
Push piston all the way forward with the aid of a plas-
tic rod (7 mm diameter), towards the opening.
2a.
Screw the refill nipple 290.3012 on and connect
the grease pump, or screw a refill nipple 290.3013 or
3014 onto the grease pump and insert the lubricator
onto the nipple. Squeeze the grease into the lubricator,
being careful not to make bubbles. Continue the filling
procedure until the piston reaches a distance of 12
mm from the end of the housing. Follow fig. 1.
fig. 1.
Do not overfill! Caution: Lever presses can create
pressure of up to 80 bar, which is enough to
destroy the dispenser.
3a.
Use closing nipple (green) if the dispenser is to be
stored.
4.
Position gas generator (make sure the O-ring is
positioned correctly) and attach firmly with a 1.5 Nm
torque key. Push the inserted cartridge forwards
slightly when tightening.
5.
Note grease type and filling date on the label.
Filling with oil
1b.
Push the piston back in the direction of the control
head, until the piston is 12 mm from the end of the
housing. Follow fig. 1.
2b.
Pour in oil through the opening at the bottom.
3b.
Position non-return valve
(yellow, article no. 5060).
4.+5. Continue as above.
Refilling with grease or oil
Unscrew gas generator (SW 21) and recycle with other bat-
teries. Never remove near an open flame! Then proceed as
instructed for the first filling.
Note
To ensure that the simalube lubricator operates reliably, only
greases that have been tested and approved for use with
the simalube should be used. In particular, it is important
to ensure the good stability of the grease against bleeding
of the base oil and a low consistency class (max. NLGI 2).
No guarantee claims will be accepted when dispensers are
filled by the user or not explicitly approved lubricants are
used. If in doubt, please contact our Technical Department
or your local distributor.
11
min. 12 mm