nected;
-
repeat the same procedure for each moving unit in the system.
NOTE: it can take up to 20 s after power-on until the safety outputs are
switched on.
In case of using the GOPAVR-GOPAVRS unit just with the safety edges
connected to it (with no GOPAVT units memorized) perform the RESET
procedure decribed below and then simultaneously press buttons A and
B for 3 s. W LEDs will turn off and the system will be ready for operation
with local edges.
If any device is replaced, all the installed devices must be RESET and the
configuration procedure repeated.
To RESET each device, do the following:
-
press button B for 3 s. Both of the SC LED indicators will flash;
-
press button B again for 3 s. Both of the SC LED indicators will flash.
Once the LED indicators have finished flashing, the unit has been reset.
WARNING: you must first RESET the fixed GOPAVR-GOPAVRS unit
and then RESET all the mobile GOPAVT units.
7. Setting frequency
If you need to use an operating frequency which is different from the
factory set frequency, you must open jumper JR2 before configuring all
the devices (see chapter 6).
If the frequency has to be changed on a system already operating with
the factory frequency, first all its moving units and the fixed unit must be
reset (see chapter 6).
8. Checking operation and radio connection
To check the operating, give an opening or closing command and press
each of the SOF sensitive edges. Check whether the movement of the
gate/door is arrested or reversed (for mobile edges, check the switching
on of SC LED on the moving unit in question and the W LED or acoustic
signal on the fixed unit; for fixed edges, check that the relative SC LED
on the fixed unit turns on). Once these operations have been successfully
completed, make sure that the wing's operational forces comply with that
which is prescribed by the EN12453-EN12445 directives.
In order to operate efficiency, the radio connection between the various
devices in an installation must be of a good quality.
You can check the quality of the radio connection between a GOPAVT
moving unit and the corresponding fixed unit by doing the following:
-
simultaneously press button A and button B, until 1 beep is emitted
(for about 3 s), on the GOPAVT moving unit to be checked;
-
the GOPAVT moving unit performs 1 to 5 transmissions to the GOPAV-
GOPAVRS fixed unit every 15 s. If a SOF safety edge is pressed, these
transmissions are signalled by a proportional number of acoustic
signals:
1x BEEP: optimum radio connection
5x BEEPs: problematic radio connection (the position or form of the
antenna must be adjusted)
-
if the quality of the radio connection is poor, the position of the devices
or the form of the antennas must be adjusted to find the configuration
that gives the best radio connection;
-
repeat the procedure for all the GOPAVT units in the installation;
-
the same function is useful for constantly displaying alarm conditions
on the GOPAVT unit in question;
-
the check function is automatically deactivated after 3 minutes.
If you cannot get a good quality radio connection using the above pro-
cedure, check the disturbance level in the communication channel by
doing the following:
-
simultaneously press button A and button B for about 3 s on the
GOPAVR/GOPAVRS fixed unit;
-
the LED indicators on the fixed unit come on. The number of lit LEDs
is proportional to the quality of the communication channel:
0 lit LEDs: very disturbed channel
6 lit LEDs: excellent channel
WARNING: if the channel is very disturbed, it is advisable to try
changing the operating frequency, see chapter 7.
9. Signals
Signal
Description
IN1
Safety edge triggered or short-
SC
circuited.
IN2
IN1
Alarm (interruption of the cir-
OC
cuit) of the safety edge.
IN2
Safety edge triggered, short-
IN1
circuited or alarm emitted
(interruption of circuit) near a
IN2
GOPAVT unit.
Missing GOPAVT unit, battery
IN1
removed from GOPAVT unit or
W
on-going remote unit presence
IN2
verification.
IN1
No GOPAVT units memorized.
IN2
Safety edge triggered (1 beep
per second until pressed safety
edge is released).
Malfunctioning alarm for 1 or
more fixed or mobile safety
edges (1 beep per second until
fault is cleared).
Battery removed on 1 or more
Buzzer
GOPAVT mobile unit alarms (1
beep per second).
GOPAVT mobile unit malfunc-
tioning alarm (1 beep every 3
seconds).
Low transmitter battery level
alarm (1 beep every 20 se-
conds).
Signal
IN1
SC
Safety edge intervention or short-circuit.
IN2
IN1
OC
Alarm (interruption of the circuit) of the safety edge.
IN2
Low battery.
Transmission to the GOPAVR-GOPAVRS fixed unit (with transmis-
Buzzer
sion check function activated, 1 to 5 beeps).
NOTE: signalling of malfunctioning on GOPAVT moving units takes place
briefly at 15 s intervals. To display them constantly, use the check function
described in chapter 8.
10. Maintenance program (every 6 months)
For the correct working:
-
keep the inside of the SOF safety edge clean and dry;
-
check operation as indicated in chapter 8;
-
replace the GOPAVT transmitter battery every 24 months or whenever
the flat battery alarm signal sets on.
6
State of relay contacts
OUT1 and/or OUT2
OPEN
OUT1 and/or OUT2
OPEN
OUT1 and/or OUT2
OPEN
OUT1 and OUT2
OPEN
OUT1 and/or OUT2
OPEN
OUT1 and/or OUT2
OPEN
OUT1 and OUT2
OPEN
OUT1 and OUT2
OPEN
OUT1 and OUT2
CLOSED
Description