ENGLISH
• Any repairs of the products must be carried out only by personnel authorized by the Manufacturer, using only original
spare parts. Failure to comply with the above can compromise the safety of the appliance.
• To ensure the efficiency of the appliance and its correct functioning, it is essential to have maintenance performed by
qualified personnel.
• If the appliance is sold or transferred to another owner or if you move and leave the appliance, always make sure that
the manual accompanies the appliance so that it can be consulted by the new owner and / or installer.
• For all appliances with options or kits (including electric ones) only original accessories must be used.
• This appliance must be used only for the purpose for which it was expressly intended. Any other use has to be
considered improper and therefore dangerous.
2.1

TECHNICAL FEATURES

The purpose of this appliance is to heat up the sanitary hot water; it can be used for systems that exploit the
principle of natural circulation.
Main parts (see FIG_02-1):
A.
Tank: it is entirely made of steel and internally subjected to a glass-coating treatment (or porcelain enamel), ie a
vitreous coating with firing at over 850 ° C.
B.
Tray: it is obtained with a co-extrusion process of layers of ABS and PMMA.
C.
Thermal insulation: made of closed cell polyurethane foam.
D.
External dome in PMMA (extruded polymethyl methacrylate sheet).
E.
Internal dome in PMMA (extruded polymethyl methacrylate sheet); it is only present in the DT02 model.
F.
Magnesium sacrificial anode: prevents tank corrosion.
G.
Combined temperature and pressure safety valve: protects the tank from possible excessive pressures caused by
expansion of the water during heating. Automatically, without the assistance of energy other than that of the hot
pressurized fluid, it discharges a quantity of fluid such as to prevent the preset pressure and temperature limits to protect
the storage tanks from being exceeded. Calibration: 700 kpa / 92 ° C.
H.
Hot water outlet.
I.
Cold water inlet.
2.2
DIMENSIONS AND DETAILS
DIMENSIONS (see FIG_02-2)
capacity
empty weight
full weight
max pressure input
max pressure accumulation
max storage temperature
absorbent surface
total area
no. domes
electrical resistance
2.3

HYDRAULIC CIRCUIT

see FIG_02-3
A. cold water inlet (3/4 "M)
B. hot water outlet (3/4 "M)
C. exhaust safety valve (3/4 "F)
Grade
inclination
width
mm
depth
mm
height
mm

TECHNICAL DATA

Cod.
L
kg
kg
kpa
kpa
° C
m 2
m 2
No
W
Pag. 13 / 40
of
14°
28°
36°
1095
1095
1095
1093
1119
1148
557
701
808
DT01
DT11
135
135
64
64
200
200
400
400
600
600
92
92
0,96
0,96
1,20
1,20
1
1
- - -
1.200
DT02
DT12
135
135
64
64
200
200
400
400
600
600
92
92
0,96
0,96
1,20
1,20
2
2
- - -
1.200