undamaged. Then bring the panel to the place where it will be installed, taking care to move it using the appropriate
handles (FIG_04-2) in order to avoid compromising the seal of the black seal that seals the cup and the tray.
The packaging elements (cardboard box, bags and plastic sheeting, staples) must not be left within reach of children as
they are potential sources of danger.
4.5

PRELIMINARY OPERATIONS

Before installation, keep the solar panel away from possible sources of damage such as bumps and accidental
drops.
Warning: before installing, never leave the solar panel upside down to avoid possible damages caused by
water infiltrations in case of rain.
Before filling, never leave the appliance exposed to direct sunlight; it is advisable to cover the solar panel.
Attention: before connecting the panel to the system proceed to a thorough cleaning of the pipes, in order to
eliminate metal residues from processing and welding, oil and grease that may be present and that, reaching up to the
panel, could alter the operation. Do not use solvents to wash the system as they could damage the system and / or its
components. Failure to follow the instructions in this manual may cause damage to persons, animals and things, for which
the manufacturer can not be held responsible.
Before filling the solar circuit, it is advisable to provide a pressure reducer if the mains pressure exceeds 6 bar.
4.6
POSITIONING
When selecting the place of installation of the appliance, follow the safety instructions below:
- Place the appliance in places where it is possible to prevent access by children as a potential source of danger for their
safety.
- Make sure that the fastening is carried out according to what is illustrated in this manual.
- Make sure that there are no high temperature parts that can come into contact with people, animals or objects that are
sensitive to high temperatures: if not, provide for safety fences
The appliance must be lifted using the appropriate handles (FIG_04-2) in order to avoid compromising the seal
of the black seal that seals the cup and the tray.
It must be positioned in a place where the breakage of any of the elements provided can not cause any
damage to people or things.
4.7
ORIENTATION
Position the appliance so that the capturing surface is exposed to the South or in any case in the east-south-west
quadrant (FIG_04-3) avoiding shading areas (FIG_04-4). The north-facing exposure affects the performance of the panels
(FIG_04-5).
4.8
GRADE OF INCLINATION
When choosing the inclination (when not required due to a sloped roof installation) take into consideration: the variation of
the inclination of the sun's rays during the year and the location of installation.
The holes on the solar panel frame (FIG_04-6) allow you to reach three different inclinations depending on the location
where the appliance will be installed:
- A-A: 11 ° tilting
- B-B: 28 ° tilting
- C-C: 36 ° tilting