Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Maintenance

CAUTION
MAKE SURE UNIT IS UNPLUGGED BEFORE ATTEMPTING ANY MAINTENANCE WORK
The following components should also be inspected regularly and well maintained.
The motor - The motors are
factory balanced and lubricat-
ed for life. They require no
maintenance.
The unit - The inside of the
unit should be wiped clean
as needed.
Condensation Pan - Units with
drain hoses should have their
line and connection checked
regularly.
Outside hoods - The outside
hoods need to be checked
every season to make sure
there are no leaves or insects
blocking the airflow.
Check
regularly that there are no
pollutants near the intake
hood. Make sure they are
clear of any snow accumula-
tion during the winter months.
filters
The filters need to be checked and cleaned once a month or when they appear dirty.
Fixed plate
Clean core on a average every 3-6 months or as needed.
a) Open access door & remove filters.
b) Carefully grip ends of core and pull evenly outward. Core may be snug, but will slide out of the
channel.
c) Wash the core in warm soapy water or light coil solution.
d) Install clean core
e) Install the clean filters
f) Replace access door
Core installation label on the outer end of the core.
To install the clean Core and Filters.
a) First mount the bottom flange of the core guide into the bottom channel approximately 1/4" (6mm)
b) Mount the left or right side flange of the core guide approximately 1/4" (6mm) followed by the other
side
c) Mount the top flange of the core guide into the top channel approximately 1/4" (6mm)
d) With all four corners in place and the core straight and even, push hard in the centre of the core
until the core stops on the back of the cabinet.
13

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Shr700Shr800Shr1200Shr1400444567

Table des Matières