scription of autodiagnostic LEDs.
Green LED
Fixed: Correct operation.
Slow blinking: Programming activated.
Quick blinking: Programming finished.
Red LED
Fixed: Programming error, go through the steps from the
beginning.
Off: Correct operation.
P
r
ogramming the converter.
The converter must be programmed with a backbone code (see page
each converter, following the steps set out below
1
0
0
If there are more converters, repeat the previous steps introducing a different backbone code for
each of them.
If during one of these processes the red LED on the converter switches on, restart programming from
the beginning.
Activate the converter programming by setting the dip switch
number 4 to ON.
The door panel will emit a tone and the green LED
on the converter will begin to slow blinking, indicating
that programming has begun.
0
Introduce the column code to program, followed by three
O.K.
zeros, then press the bell button.
To indicate that the equipment has been correctly
programmed, the door panel will emit a tone and the
green LED on the converter will begin to quick blinking,
indicating that programming has begun.
Exit programming by setting the dip switch number 4 to OFF
and pressing the C button on the door panel.

AUTODIAGNOSTIC LEDS

The autodiagnostic LEDs are placed next to
the configuration dip switch.
PROGRAMMING
.
Access the door panel programming mode, pressing
the key button followed by the installer secret code
(factory default 1315), just as indicated in the
door panel manual.
35
), which must be different for