INSTALLATION OF REPLACEMENT
Coming from previous page
Installation with multiplexer
Riser 1
dC
dB
See operation modes, configuration, programming and installation in the TMC-V2PLUSML instructions manual.
Cables and sections
2
2
0,25mm (twisted).
2
0,5mm (twisted).
2
1mm (twisted).
2
1,5mm
(twisted).
2
0,18mm (multipaired).
0,18x2= 0,36mm (multipaired).
0,18x4= 0,72mm (multipaired).
2
Rap-2150 1mm (twisted).
*
1 par UTP Cat 5 0,18mm.
2 par UTP Cat 5 0,18x2= 0,36mm.
4 par UTP Cat 5 0,18x4= 0,72mm.
Use Golmar RAP-2150 cable, for new installations.
*
Several accesses and risers (with multiplexers)
Monitor V2Plus
dD
Monitor V2Plus
MC-V2PLUS
2
dF=3m./1,5mm
FA-V2PLUS
S
P LU
V 2
C -
M
Door panel-V2PLUS
P
FA-V2PLUS
dA
Cables and distances chart
dA
10m.
20m.
40m.
50m.
5m.
2
10m.
2
25m.
40m.
2
5m.
2
10m.
2
25m.
Installation with multiplexers
in daisy chain and monitors B/W
Riser 1
dC'
V 2
C -
M
MC-V2PLUS
dG=3m
V 2
C -
M
dB'
Door panel-V2PLUS
dB
dD
dC+dD
50m.
15m.
40m.
100m.
15m.
70m.
100m.
15m.
100m.
150m.
15m.
100m.
35m.
15m.
25m.
70m.
15m.
50m.
100m.
15m.
100m.
200m.
15m.
150m.
35m.
15m.
25m.
70m.
15m.
50m.
100m.
15m.
100m.
Monitor
V2Plus B/W
dD
Monitor
V2Plus B/W
MC-V2PLUS
daisy chain
2
dF=3m./1,5mm
FA-V2PLUS
S
P LU
2
dF=3m./1,5mm
FA-V2PLUS
S
P LU
P
FA-V2PLUS
dA
dB'
dC'+dD
37m.
26m.
75m.
46m.
75m.
67m.
112m.
67m.
26m.
16m.
52m.
33m.
75m.
67m.
150m.
100m.
26m.
16m.
52m.
33m.
75m.
67m.
41