QV30 - QV40 - QV52
QUADRO VINO has been designed to be hung on a wall. It is necessary to fix two hooks on the wall by using the appropriate plugs for the type of
wall in question (perforated brick , concrete, drywall etc. ..) and depending on the weight it can support (specified on plugs). The manufacturer
declines any liability in regards to product installation.
The following plan illustrates how far apart the two plugs should be installed (D) . Height (H1) as indicated in the diagram refers to the suggest-
ed height to drill the plug holes (this may vary according to specific needs). Height (H2) refers to the power socket position.
QV30
470 mm
100 - 240 V
• Hang Quadro Vino by setting the hooks in the slots on the back of the case.
• Insert the plug in the socket (see safety electrical system)
• Assemble the door following the instructions given in point 6 of the general information
TEMPERATURE SETTING, USE AND OPERATION
• To start refrigerating, press the main switch on the top panel of QUADRO VINO
In the NON REFRIGERATED model the main switch turns on and off the light (not timed)
• The electronic card has a delta of 2 °C so that if the set temperature is 12 °C the system will stop once it reaches the set temperature of 12 °C
and will start again as soon as the temperature reaches the 14 °C.
• Lights will automatically turn off 12 hours after switching on.
LEGEND: CONTROL ICONS
(pressed and released): light switch
(hold 3 seconds): check or set temperature
To raise temperature
To lower temperature
To set temperature.
Hold the
button for 3 seconds • The set point will be visible and the
buttons • Press
button to set new value or wait 15 seconds to leave setting mode.
Problem
Device does not switch on
Cooling is not efficient
Lighting does not work
Controller display is off
If the issue persists, please refer to our website www.exposrl.com and the following links:
Document
Exploded view
Wiring diagram
User manual
INSTALLATION
D
155 mm
TROUBLESHOOTING
Potential cause
Device is unplugged
Ambient temperature is too high
The door is frequently opened or
closed incorrectly
Set temperature is incorrect
Side switch is in OFF position
Main switch is in OFF position
www.exposrl.com >> technical area >> parts and exploded
www.exposrl.com >> technical area >> wiring diagrams
www.exposrl.com >> technical area>> user instructions
QV40
QV52
100 - 240 V
LEGEND: LEDS
LED will start flashing • To set the value press
Browser link
ENGLISH
D
650 mm
70 mm
(Continuous): device is on
(Flashing): setting
(Continuous): defrosting
Solution
Check device is plugged in
Eliminate the causes
Switch it ON
Turn main switch ON
File name
QV30 - QV40 - QV52 ( EV )
QV30 - QV40 - QV52 ( SE )
QV30 - QV40 - QV52 ( MM )
or