Device is equipped with following temperature control system:
Ambient temperature sensor together with water inlet temperature sensor are connected together
to take care of freezing protection in low temperatures.
Water inlet temperature sensor turns off the heater when set temperature is reached. Normal
heating cycle starts when water inlet temperature drops 2 degrees below the set temperature
(factory default).
Water outlet temperature sensor protects the heater from overheating and also from too big
temperature difference between in and out.
Overheating sensor protects the heater.
Protection mechanism:
Flow switch after the heater element.
Mechanical overheat protection shuts off the heater.
If one of these control systems breaks (malfunction, switch off or measured value of limits) a message is
shown on the display. See table error codes. (Table 2 – )
WARNING:
Turning of for bypassing any of these systems voids the warranty.

Electric diagram

Power
supply
Ele ctri c heate r
E
Water pump
Image 17 – Electric diagram
Tubtainer 2 heater/filter system
50/108
SYSTEM SAFETY SETTINGS
22.12.2020
Over hea t Temp.
Water inlet Temp.
Water outlet Temp.
P
14/17