© Kirami Oy, Finland
Device is equipped with following temperature control system:
Ambient temperature sensor together with water inlet temperature sensor are connected together
•
to take care of freezing protection in low temperatures.
Water inlet temperature sensor turns off the heater when set temperature is reached. Normal
•
heating cycle starts when water inlet temperature drops 2 degrees below the set temperature
(factory default).
Water outlet temperature sensor protects the heater from overheating and also from too big
•
temperature difference between in and out.
Overheating sensor protects the heater.
•
Protection mechanism:
Flow switch after the heater element.
•
Mechanical overheat protection shuts off the heater.
•
If one of these control systems breaks (malfunction, switch off or measured value of limits) a message is
shown on the display. See table error codes. (Table 2 – )
WARNING:
Turning of for bypassing any of these systems voids the warranty.
Electric diagram
Power
supply
Ele ctri c heate r
E
Water pump
Image 17 – Electric diagram
Tubtainer 2 heater/filter system
50/108
SYSTEM SAFETY SETTINGS
22.12.2020
Over hea t Temp.
Water inlet Temp.
Water outlet Temp.
P
14/17
AGE