Method Of Operation; Measuring Procedure - Bosch D-tect 150 Consignes De Fonctionnement/Sécurité

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Dtect150_1609929X08_3-15.qxp_D-tect150 3/20/15 10:53 AM Page 11

METHOD OF OPERATION

(SEE FIGURE B)
The detection tool checks the
base material of sensor area 9 in
measurement direction A to the
displayed
A
Measurement is possible only
S E
S E
during movement of the detection
N S
N S
O R
O
O
tool in the direction of travel B
and for a measuring distance of
9
at least 4" 10 cm. Move the
detection tool in a straight line
B
with light pressure over the wall
so that the wheels remain in firm contact with
B
the wall. The object depth and, if possible, the
object material, are indicated on the display.
Optimal results are achieved when the measured
distance is at least 15 3/4" (40 cm) and the
detection tool is moved slowly over the entire
location. This method of operation ensures
reliable detection of outer object edges that run
transverse to the detection tool's movement
direction.
Always move crossways over the area to be
checked.
If several objects are located one over the other in
the wall, the object that is indicated in the display
is the one nearest to the surface.
The representation of the material types of
detected objects in the display 16 can deviate
from the actual object material types. This applies
particularly for very thin objects, which are
represented thicker in the display. Large
cylindrical objects (e.g. plastic or water pipes) can
appear in the display smaller than they actually
are.
Detectable Objects
– Plastic pipes (e.g. water-filled plastic pipes, as
used in floor/wall-heating systems, with at least
3/4" in diameter; empty pipes with at least 1" in
diameter)
– Electrical wiring (independent of whether
carrying voltage or not)
– Three-phase wiring (e.g. to the stove)
– Low-voltage
wiring
telephone)
– Metal pipes, bars, studs of any type (e.g. steel,
copper, aluminium)
– Reinforcing steel
– Wooden studs
– Hollow spaces
Measurements possible
– In concrete/reinforced concrete
– In brickwork (bricks, porous concrete, foam
concrete, aerated concrete, lime-sand brick)
– In light construction walls
measuring
depth.
(e.g.
for
door
bell,
-11-
– Under surfaces such as stucco, tiles, wallpaper,
hardwood flooring, carpet
– Behind wood, drywall
Special Measuring Cases
Based on the measuring priniciple, unfavorable
conditions can influence the measuring result, for
example:
– Multi-layered walls
– Empty plastic pipes and wood studs in hollow
spaces and light construction walls
– Objects running inclined in walls
– Moist walls
– Metal surfaces
– Hollow spaces in a wall; these can be indicated
as objects.
– Closeness to equipment that generates a
strong magnetic or electromagnetic field, e.g.
radio stations or generators.

MEASURING PROCEDURE

Switch the detection tool on. The "standard start
display" appears on display 16.
Move
Sensor
0 cm
2
4
6
8
P
e r
v
Concrete
Position the detection tool against the wall and
move it over the wall in the direction of travel (see
"Operation Instructions", page 13). Measured
results are indicated on display 16 after a
minimum measuring distance of 4" (10 cm). To
ensure correct measurement results, move the
detection tool slowly and completely over the
assumed object in the wall.
If the detection tool is lifted away from the wall
during a measurement or not operated (moving
the device or pressing a button) for more than 2
minutes, the last measured result remains on the
display. "Hold" appears on the sensor-range
indicator c. When the detection tool is placed
against the wall again, moved on or when the start
button 11 is pressed, the new measurement will
start.
When LED 17 lights up red, an object is in the
sensor range. When LED 17 lights up green, no
object is in the sensor range. When LED 17
flashes, "live" wires / conductors are in the
sensor range.
0 cm
2
4
6
8
N
e
t x

Publicité

Table des Matières
loading

Table des Matières