Maximum 058-9318-6 Mode D'emploi page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PROBLEM
Regulated pressure gauge
indicates abnormal pressure
drop when the air tool is being
used.
Air leaks from the pressure
regulator or the regulator is
not working properly.
Pressure relief valve is opened.
NOTE:
If there is any damage to pump components, please contact
1-888-670-6682 for assistance.
200-2952-B_ALA1983012 MAXIMUM MANUAL_VR_120616.indd 23
POSSIBLE CAUSES
1.
This is normal condition.
2.
Compressor capacity is
low.
1.
Internal parts of the
regulator are dirty or
damaged.
1.
Tank pressure exceeds
normal operating pressure.
Refer to technical
specifications on page 6.
2.
Pressure switch is not
operating properly.
SOLUTIONS
1.
If pressure drops too
low, adjust the pressure
regulator knob while using
the air tool.
2.
Check the air requirement
of air tool. Refer to
technical specifications
on page 6. If it is higher
than CFM and pressure
supplied by compressor,
use a compressor of high
capacity. Most tools are
rated at 25% of actual
CFM while running
continuously.
1.
Replace the regulator or
internal parts.
1.
Replace the pressure
switch.
2.
Replace the pressure
switch.
23
TM
1/24/2017 8:28:23 AM

Publicité

Chapitres

Table des Matières
loading