Maintenance Intervals
Component
Work to be carried out
Complete unit
Check for leaks and correct operation
Clean
Manometer
Test the accuracy of the indication
1) To be carried out by DrägerService or trained personnel.
Storage
Observe DIN 7716, "Guidelines for Storage, Servicing and Cleaning of
Rubber Products".
Technical Data
Test case
Dimensions (length x width x height)
Weight
Manometer
Operating position
Accuracy class
Pressure range
Scale divisions
Overpressure resistance
Vacuum resistance
Ambient conditions
Temperature
Accessory: compressed-air gun
Maximum input pressure
Air connector
Length of connecting hose
6
Each time before a chemical
protection suit is tested
Order List
Designation and description
Porta Control, complete
420 x 340 x 115 mm
3.7 kg
Horizontal
1.6
–10 mbar to 25 mbar
0.5 mbar
Accessory required for operation
3 times the pressure range
10 times the vacuum range
For testing small suit valves
(diameter 36 mm with screw cap)
–10 °C to 25 °C
10 bar
to fit safety plug connectors
of the Dräger compressed-
air breathing systems
1) See list of spare parts
3 m
2) Not included in the Porta Control
After testing
X
including:
mechanical manometer
1)
test volume
1)
testing hose
plugs (2 pieces)
hose clamps (2 pieces)
stopwatch
testing caps (2 pieces)
testing plugs
pump ball
connecting hoses (2 pieces)
2)
:
Compressed-air gun
2)
connecting sleeve
sealing plug
testing caps (2 pieces)
set of sealing washers (2 pieces)
Annually
X
1)
X
Order No.
R 53 340
R 53 466
12 94 091
R 50 866
D 40 888
R 53 289
R 53 287
R 50 336
11 80 819
R 51 034
R 52 693
R 52 694
R 50 563
T 40 477