Pruebas Y Ajustes; Pruebas - Garland GF Serie Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PRUEBAS Y AJUSTES

TO INLET OF SALAMANDER/
CHEESEMELTER MANIFOLD
FOR LEFT-MOUNTED SALAMANDER/CHEESEMELTER
SUBSTITUTE COMPONENTS SHOWN FOR ITEM 17 CIRCLED IN ADJACENT VIEW
TO INTER-CONNECT TUBING ( ITEM 18 - 4531608)
ATTACH SUPPORT CLAMP (ITEM 10 - 2640800)
TO SUPPORT BRACKET (ITEM 9 - 4531602)
17
WITH (2) #10-24 SELF-TAPPING SCREWS (ITEM 1
F32 - NOT SHOWN) PROVIDED
10
6
9
MARK HOLE LOCATIONS AND MOUNT
SUPPORT BRACKET (ITEM 9 - 4531602 ) TO RANGE
BACK WITH (2) #10-16 TEKS SELF-DRILL/TAP
SCREWS (ITEM 14 - F67 - NOT SHOWN) PROVIDED.
18
4531608
17
3013000
16
G01474-9
15
G01738-11
14
F67
13
G01738-14
12
G01738-16
11
3012800
10
2640800
9
4531602
8
4530189
7
076029-171
6
G01474-5
5
G01738-5
4
076029-204
3
2127503/2127500
4.5"wc 3/4"NPT REG. NATURAL GAS/10"wc 3/4"NPT REG. PROPANE GAS - PROVIDED WITH SALAMANDER/CHEESEMELTER
NAT: 4522421/4525049
2
4.5" wc 1" NPT/ 1" ISO 7-1 REG. NATURAL GAS OR 10"wc 1"NPT/1" ISO 7-1 REG. PROPANE GAS - PROVIDED WITH RANGE
PRO: 4522422/4525050
1
F32
ITEM NO.
PART NUMBER

Pruebas

Todas las conexiones de los accesorios y tuberías deberán
ser probadas para asegurarse de que no existan fugas. Utilice
detectores de fugas de gas aprobados, una solución de
jabón o equivalentes para hacer pruebas sobre y alrededor
de todas las conexiones de los accesorios y tuberías. ¡NO
USE UNA LLAMA! Para tener acceso a todas las líneas de gas
y a los accesorios se requiere que el/los panel(es) de válvula,
el/los panel(es) delantero(s) inferior(es), y/o la(s) rejilla(s)
de los hornos sean retirados. Pudiera ser necesario quitar,
o por lo menos levantar y apuntalar bien la(s) plancha(s),
las plancha(s) de calor uniforme ("hot tops"), y/o la(s)
rejilla(s) superior(es). Todas las partes retiradas, (incluso los
sujetadores), deberían ser debidamente resguardadas para
poder volver a rearmar las partes.
1
Asegúrese de que todas las válvulas y los termostatos
están la posición apagada ("OFF").
Página 56
16
13
12
TO OUTLET OF SALAMANDER/
CHEESEMELTER REGULATOR
ATTACH SUPPORT CLAMP (ITEM 10 - 2640800)
TO SUPPORT BRACKET (ITEM 9 - 4531602)
WITH (2) #10-24 SELF-TAPPING SCREWS (ITEM 1
F32 - NOT SHOWN) PROVIDED
MARK HOLE LOCATIONS AND MOUNT
SUPPORT BRACKET (ITEM 9 - 4531602) TO
BACK WITH (2) #10-16 TEKS SELF-DRILL/TAP
SCREWS (ITEM 14 - F67 - NOT SHOWN) PROVIDED.
3/4" X 51" X 33" TUBING
3/4" CC X 3/4" NPT STRAIGHT FITTING
3/4" NPT X 1/2" NPT 90 DEG. REDUCING ELBOW
3/4" NPT X 3.5" PIPE NIPPLE
SCREW - #10-16 X 1/2" HEX WASHER HEAD TEKS SELF-DRILL/TAP (NOT SHOWN)
3/4" NPT X 2.000 PIPE NIPPLE
3/4" NPT X 22.750 PIPE NIPPLE
1" NPT X1" NPT X 3/4" NPT REDUCING TEE
PIPE SUPPORT BRACKET CLAMP
PIPE SUPPORT BRACKET 48/60
1" NPT PIPE UNION
1" NPT 90 DEGREE ELBOW(SUPPLIED WITH RANGE)
90 DEGREE ELBOW 3/4" NPT
3/4" NPT X 6.5" PIPE NIPPLE
1" NPT X 2" PIPE NIPPLE (ONE SUPPLIED WITH RANGE)
SCREW - #10-24 X 1/2" PAN HD SELF-TAP TYPE F (NOT SHOWN)
DESCRIPTION
NOTE: CUT TUBING (ITEM 18 - 4531608) TO SIZE AS REQUIRED
TO SUIT SALAMANDER/CHEESEMELTER TOP OR REAR
MANIFOLD INLET CONNECTION
17
18
6
5
15
6
10
9
2. Encienda la válvula de suministro de gas principal.
Encienda todos los pilotos de la sección superior.
3. Haga pruebas de fugas a todas las válvulas y accesorios
tal como se describió a principios de esta sección. Corrija
cualquier fuga que se detecte y vuelva a realizar las
pruebas.
4. Encienda el piloto del horno.
5. Ajuste el termostato del horno al máximo. Haga pruebas
de fugas a todas las válvulas y accesorios tal como se
describió al inicio de esta sección. Corrija cualquier fuga
que se detecte y vuelva a realizar las pruebas.
6. Cierre todas las válvulas y ajuste el dial del termostato
a la posición apagada ("OFF") o a la más baja. Todas las
unidades son probadas y ajustadas en la fábrica; sin
embargo, los quemadores y los pilotos deberán ser
comprobados al instalarse y ajustarse de ser necesario.
17
REGULATOR - 6.0"w.c.
3
NATURAL GAS OR 10.0"w.c.
PROPANE GAS (SUPPLIED
WITH SALAMANDER/CHEESEMELTER)
SUPPLIED WITH
7
RANGE
SUPPLIED WITH
4
RANGE
2
REGULATOR - 4.5"w.c.
NATURAL GAS OR 10.0"w.c.
PROPANE GAS (SUPPLIED
WITH RANGE)
4
8
4
11
1
2
1
1
4
1
1
1
2
Optional Interconnect Gas Kit
2
1
48in (1200mm) & 60in (1500mm) G/U/X
1
3
Part # 4531606
1
3
1
1
4
QTY
Parte # 4525587 Rev 5 (11 Mar 19
TO INLET OF RANGE
MANIFOLD
1" NPT GAS SUPPLY
CONNECTION

Publicité

Table des Matières
loading

Table des Matières