TROUBLE SHOOTING GUIDE (TABLE 3)
Problem
Probable Cause
Cable kinks or breaks.
Operator forcing the cable.
Too much slack between machine and drain. Do not allow more than six inches between machine and drain.
Cable used in wrong size drain line.
Cable exposed to acid
Cable tangles in container.
Operator forcing the cable.
Failure to feed.
Feed Rollers frozen.
Cable tangled in drum.
Motor does not run.
Trigger in neutral (off) position.
Motor turns in one direction
Reverse switch failure.
but not other.
See pages 23 and 24 for Parts List and Schematic Diagram.
Solution
Do not force the cable. Let the cutter do the work.
A cable that is too large or too small in diameter for a line is more
likely to kink. (Consult Table 1—Cable Applications.)
Clean and oil cables regularly.
Do not force the cable. Let the cutter do the work.
Clean and lubricate feed rollers regularly. Replace worn rollers.
Use proper cable size. (Consult Cable Application Chart—Table 1).
Switch Trigger to either Forward or Reverse.
Replace reverse switch.