Equipment Specifications
Minimum/Maximum Operating Temperature*
Minimum/Maximum Operating Pressure*
Maximum Continuous Flow Rate for Lead & PFOA/PFOS Reduction**
Maximum Flow Rate for Chlorine Reduction***
Maximum Flow Rate for Chloramine Reduction***
Inlet and Outlet Connection Size/Type
Unfiltered Water Housing Drain Port Connection Size/Type
Filter Housing Body Material
Inlet Pressure Gauge Port
Inlet Pressure Gauge Included
Swing Bolts (Lid) Material
O-ring (Lid) Material
O-ring (Plumbing Adaptors) Material
Nominal Micron Rating
Filter Housing Anchor Kit Included
Number of Filter Cartridges
Filter Cartridge Media Type
Filter Cartridge End Cap Material/Color
Filter Cartridge Top Endcap Includes Handle
Filter Cartridge O-ring (Dual) Material
Maximum Allowable Filter Cartridge Pressure Drop
Flow Monitor Display Type
Flow Monitor Capacity
Positive Indication of Flow
Flow Monitor Alarm at "0" Gallons Remaining
Flow Monitor Power Supply
Low Battery Alarm
Flow Meter Type
Flow Meter Connection Size/Type
Flow Meter Body Material
* Minimum and Maximum Operating Temperatures and Pressures listed above apply to complete system as well as all individual components including
filter housing, filter cartridge and volumetric flow monitor/meter.
** See Certified Substance Reduction for specific flow and reduction claims.
*** Claims are not performance tested or certified by IAPMO. Performance claims are based on independent laboratory and manufacturer's internal test
data. Actual performance is dependent on influent water quality, flow rates, system design and application. Results may vary. See Certified Substance
Reduction for certified chlorine flow and reduction claims.
Flow Rate and Pressure Drop
30
25
20
15
10
5
0
1
2
3
6
IOM-WQ-BB-S100
SYSTEM MODEL NO. BB-S100
During Water Flow: Visual- Flashing "0 gal" on Display/ Audible- Beeping Alarm
Flow Rate and Pressure Drop
4
5
6
7
Flow Rate (GPM)
2130
34 to 125°F / 1 to 52°C (125°F / 52°C at 80psi Maximum Pressure)
25psi to 125psi / 172 kPa to 861 kPa
4 GPM (15 lpm)
13 GPM (49.2. lpm)
7 GPM (26.4 lpm)
1" NPT
½" FNPT
Glass Reinforced Polypropylene
1⁄4" FNPT Brass Reinforced
Yes
304 Stainless Steel
EPDM
EPDM
0.5 Micron Nominal
Yes- 3/8" Concrete Anchors (X3)
1
Lead Adsorption Carbon Block
Glass Reinforced Polypropylene/Green
Yes
EPDM
40psi Drop
5 Digit LCD- Volumetric Count Down to "0"
84,480 Gallons (Resettable / Non Programmable)
Yes- Flow Wave Icon On Display
2 AA Alkaline Batteries
Yes- Visual Low Battery Icon and Audible Beeping Alarm
Inline Flow Through Turbine Meter
1" x 1" MNPT
Glass Reinforced Polymer
8
9
10
11
EDP# 68110146
Low Pressure Drop
The Watts BB-S100 system uses
a large, high capacity carbon block
filter cartridge to ensure the highest
degree of performance while offer-
ing the highest possible flow rate at
the lowest possible pressure drop.
12
Pressure drop testing conducted
at Watts' Peoria, AZ facility using
approximately 73ºF water. Test
results reflect new filter cartridge
flow rate and pressure drop perfor-
mance.
© 2021 Watts