OBJ_BUCH-1321-001.book Page 13 Thursday, January 13, 2011 2:35 PM
Action
Switching On and Off
Connecting a power tool to the vacuum cleaner; remote automatic
switching
Regulating the airflow
Blower function
Semi-automatic filter cleaning
Changing the folded filter
Cleaning the float
Selecting accessories
Troubleshooting
Switch the vacuum cleaner off immediately
as soon as foam or water comes out, and
empty the container. Otherwise, the vacuum
cleaner can become damaged.
The vacuum cleaner is equipped with a
float. When the maximum filling height is
reached, the suction capacity is reduced.
Set the On/Off switch to position "0" and
empty the container.
If the suction force is so high that the con-
nected power tool adheres too firmly
against the working surface, regulate the
airflow.
When the vacuum performance decreases,
activate the semi-automatic filter cleaning.
Maintenance and Cleaning
For safe and proper working, always keep
the vacuum cleaner and ventilation slots
clean.
A dust-technical inspection is to be carried out
at least once every year by the manufacturer or
an instructed person, e. g. for damage of the fil-
ter, tightness against leakage of the vacuum
cleaner and function of the control/monitoring
unit.
For category L vacuum cleaners that were in
contaminated environments, the exterior as well
as all machine parts should be cleaned or treat-
ed with sealants. When performing maintenance
and repair work, all contaminated components
Bosch Power Tools
Figure
8
9
10
11
12
13
14
–
that cannot be cleaned to satisfactory must be
disposed of. Such components must be dis-
posed of in impermeable plastic bags conform-
ing with the valid regulations for the disposal of
such waste.
For maintenance on behalf of the user, the vac-
uum cleaner must be disassembled, cleaned
and maintained as far as feasible, without caus-
ing a risk for the maintenance personnel or oth-
er persons. Prior to disassembly, the vacuum
cleaner should be cleaned in order to prevent
any risks. The room/enclosure in which the vac-
uum cleaner is disassembled should be well
ventilated. Wear personal protective equipment
during maintenance. After the maintenance, the
maintenance area should be cleaned.
If the vacuum cleaner should fail despite the
care taken in manufacturing and testing proce-
dures, repair should be carried out by an after-
sales service centre for Bosch power tools.
If the replacement of the supply cord is neces-
sary, this has to be done by Bosch or an author-
ized Bosch service agent in order to avoid a safe-
ty hazard.
After-sales Service and
Customer Assistance
Our after-sales service responds to your ques-
tions concerning maintenance and repair of your
product as well as spare parts. Exploded views
and information on spare parts can also be
found under:
www.bosch-pt.com
1 609 929 X19 | (13.1.11)
English | 13
Page
171
172 – 174
174
175
176
177 – 178
179 – 181
182