4. Mounting the quick-change push-head adapter
Attaching the quick-change push-head adapter
·
The M10 female thread of the rod-end piece (1) must be visible and in
perfect condition.
·
Attach the cone ring (2) with the cone area pointing downwards.
·
Place a star (4) on the top section of the push-head adapter (3). Then push
the top section, with the star being attached, onto the end piece of the
rod. The clamping plate in the adapter locks the push-head adapter into
place.
Removing the push-head adapter
·
Grasp the recess (5) at the top of the push-head adapter with your thumb
and index finger and withdraw the clamping plate.
·
You can now remove the top section.
10
Hotline: +49 2953 73-211
Fax: +49 2953 73-250
Wöhler Viper 42