12.2 Noise emission
Device type
Idling (measured at a distance of 1 m,
according to EN)
Full load (measured at a distance of 1 m,
according to EN)
Idling (measured at a distance of 4 m,
according to NFPA)
Full load (measured at a distance of 4 m,
according to NFPA)
12.3 Operating and storage temperature ranges
Device including rechargeable battery
Operating temperature, standard
Operating temperature extreme
range for 9 min., cyclical (device
operational)
Storage temperature, standard
(device not operational)
Ambient temperature extreme range
for 7 min. (device not operational)
12.4 Oscillation / vibration
The total oscillation value / vibration value to which the upper limbs are exposed, is usually
below 2.5 m/s².
Higher values may be measured for short periods as a result of interaction with the materials
to be processed.
(The oscillations / vibrations were determined in accordance with DIN EN ISO 20643.)
12.5 Torque specification and wrench size for pivot bolt
Device type
Pivot bolt
Wrench size
Torque
[°C] / [°F]
[°C] / [°F]
[°C] / [°F]
[°C] / [°F]
e100 / le100
M 20 x 1.5
[mm]
30
1.18
[in.]
[Nm]
100 +10
885 + 89
[lbf∙in]
[dB(A)]
[dB(A)]
[dB(A)]
[dB(A)]
-20 ... +55
-20 ... +120
-25 ... +45
-30 ... +150
77
e100 / le100
-
-
67
70
-4 ...
-4 ...
-13 ...
-22 ...
+131
+250
+113
+300