Lukas STRONGARM e100 Manuel D'utilisation page 72

Appareils multifonction
Masquer les pouces Voir aussi pour STRONGARM e100:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

10.3.2 Replacing the handle
1. Unscrew the two attachment screws with an Allen key.
2. Remove the lower part of the handle while holding the upper part. Then take off the
upper part.
3. Position the new handle and hold it, while mounting the lower part with the attachment
screws (use medium strength thread lock e.g. LOXEAL® 54-03 or Loctite 243).
10.3.3 Replacing the blade arms
1. Close the blade arms so that the tips are almost touching and remove the battery.
2. Remove protective cover as described before.
Attachment screw
72
Attachment
screw
(hex socket head)