18
Calibration
The meter needs to be calibrated and tested on a regular basis to
ensure it produces accurate measurement results. We recommend
carrying out calibration once a year.
Technical data
Function
DC voltage
AC voltage
DC current
AC current
Resistance
Capacitance
24
EN
Range
400.0 mV
4.000 V
40.00 V
400.0 V
600 V
400.0 mV
4.000 V
40.00 V
400.0 V
600 V
10A
10A
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
40.000 nF
400.0 nF
4.000 µF
40.00 µF
100.0 µF
10 A/600 V
quick-acting
Accuracy
± (0.5% rdg ± 2 digits)
± (1.2% rdg ± 2 digits)
± (1.5% rdg ± 2 digits)
± (1.5% rdg ± 4 mV)
± (1.2% rdg ± 2 digits)
± (1.5% rdg ± 3 digits)
± (2.0% rdg ± 4 digits)
± (2.5% rdg ± 5 digits)
± (3.0% rdg ± 7 digits)
± (1.2% rdg ± 4 digits)
± (1.0% rdg ± 2 digits)
± (1.2% rdg ± 2 digits)
± (2.0% rdg ± 3 digits)
± (5.0% rdg ± 50 digits)
± (3.0% rdg ± 5 digits)
± (5.0% rdg ± 5 digits)