8
Diode test
To test the diode, turn the rotary switch
to position „Ω" and press the „Mode"
button once to activate the „Diode test"
function. Then connect the measuring
contacts to the diode. The measured
value acquired for the forward voltage
appears on the display. If „O.L." appears
on the display instead of a measured
value, the diode has either been tested
in the reverse direction or is faulty. If
0.0 V is measured, the diode is faulty
or a short-circuit has occurred.
9

Capacitance measurement

To take a capacitance measurement, turn
the rotary switch to position „CAP" and
press the „Mode" button three times to
activate the „Capacitance measurement"
function. Then connect the measuring
contacts to the object to be tested.
In the case of poled capacitors, connect
the positive pole to the red test prod.