Indicator status
Red
Green
LED
LED
Flashing Off
Flashing Flashing Fault
GB
On
On
Anl_PE_AHS_18_Li_SPK7.indb 242
Anl_PE_AHS_18_Li_SPK7.indb 242
Explanations and actions
Adapted charging
The charger is in gentle charging mode.
For safety reasons the charging is performed
less quickly and takes more than 1 hour. The
reasons can be:
- The battery pack has not been used for a very
long time or an already fl at battery was further
discharged (exhaustive discharge).
- The battery pack temperature is outside the
ideal range (between 10° C and 45° C).
Action:
Wait for the charging to be completed; you can
still continue to charge the battery pack.
Charging is no longer possible. The battery
pack is defective.
Action:
Never charge a defective battery pack.
Take the battery pack out of the charger.
Temperature fault
The battery pack is too hot (e.g. due to direct
sunshine) or too cold (below 0° C).
Action:
Remove the battery pack and keep it at room
temperature (approx. 20° C) for one day .
- 242 -
22.09.2017 12:10:25
22.09.2017 12:10:25