Motion Detector Walk Test - Honeywell Home RCA902N Directives D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Motion Detector Walk Test

IMPORTANT: Before commencing walk test ensure the LED indicator behind the
detector lens is not flashing continuously. If it is wait until the detector has complet-
ed its warm-up cycle and the flashing stops.
Configure the detector for walk testing according to the selected Day or Night oper-
ating mode as follows:
1) Set the TIME control fully counter-clockwise to its minimum setting.
2) If the detector is set to DAY operation (for use with a chime), adjust the DUSK
control fully counter-clockwise to its minimum setting. If the detector is set to
NIGHT operation (for use with lighting) adjust the DUSK control fully clockwise
to its maximum setting.
DUSK CONTROL
DUSK CONTROL
SETTING FOR
SETTING FOR
NIGHT OPERATION
DAY OPERATION
Fig. 5
9
TIME
CONTROL
M27297