TROUBLESHOOTING MR5000

Indicator Light Description
Flashing green
Power/Standby
Constant green
Constant yellow
Flashing red
Constant red
Flashing green
Fence
Flashing red
Fault
Energizer doesn't operate
Electric fence voltage is below
3000V or your stock are
escaping
Save these instructions.
Causes
Turbo mode
Energizer is operating at normal power
Low power
Electrical interference preventing
Energizer receiving clear Remote signal.
Remote has switched Energizer to
Standby mode.
Voltage is greater than 1.0kV
Voltage is less than 1.0kV. The
Energizer is reaching its limit for
effective animal control.
Pos si ble Cause(s)
Energizer Off
Break in supply circuit
Faulty Energizer
Inadequate earthing
Short on the fence line
Faulty Energizer
Solution
None
None
None
Self corrects when interfeence reduces.
Reduce sensitivity via switches (see
illustration with "Remote Control
electrical interference" section).
Use Remote to switch Energizer ON
again or reset the power supply.
None
Fence maintenance is urgently required.
So lu tion
Switch ON
Test power point
Have Energizer repaired
Improve the earth system by adding more galvanised earth
stakes to the earth system until the earth voltage is 200V
or below.
Check the electrical con nec tions are secure, eg. from the
fence to the red terminal, from the earth system to the
green terminal, at gates etc.
Check the voltage on the fence every 33m (100ft) using
the Digital Volt Meter (G5030). Note if the voltage is
dropping. The closer to a fault, the lower the voltage
reading will be. Become aware of things that cause faults
and always be on the lookout for: stray pieces of wire on
the fence, heavy vegetation growth, cracked or broken
in su la tors, broken wires.
Unplug the Energizer from the power supply and remove
the fence wire from the Red terminal. Plug Energizer
in again. Using a Digital Volt Meter (G5030) check the
voltage across the ter mi nals. If the voltage is less than
5000V, have Energizer repaired.
9