5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Warning!
Always pull the power plug before making
adjustments to the equipment.
6.1 Connecting the intake line
As a basic principle, we recommend the use of
a preliminary fi lter and a suction set with suction
hose, suction strainer and non-return valve, in
order to prevent long priming periods and unne-
cessary damage to the pump as a result of stones
and solid foreign bodies.
•
The intake hose or pipe should have a mi-
nimum diameter of approx. 25 mm (1"); a
diameter of approx. 32 mm (11/4") is recom-
mended for suction heights exceeding 5 m.
•
Connect the intake valve (foot valve) with in-
take cage to the intake line.
•
Position the intake line so that it rises from
the water withdrawal point to the equipment.
Avoid positioning the suction pipe higher than
the pump, as this would delay the escape of
air bubbles from the suction pipe and impede
the priming process.
•
Install the intake and discharge lines in such
a way that they do not exert any mechanical
pressure on the equipment.
•
The intake valve should be low enough in the
water to ensure that if the water level falls, the
equipment will not run dry.
•
A leaking intake line will draw in air and there-
fore not draw in any water.
6.2 Connecting the discharge line
•
The discharge line approx. 19 mm (3/4") must
be connected to the approx. 33,3 (R 1IG)
discharge line connector of the equipment
either directly or with the aid of a threaded
nipple.
•
With the right couplings it is also possible, of
course, to use a approx. 13 mm (1/2") delive-
ry hose. The smaller delivery hose results in a
lower delivery rate.
•
During the priming operation, fully open any
shut-off mechanisms (spray nozzles, valves,
etc.) in the pressure line so that the air can
escape without obstruction.
Anl_GC-WW_6036_SPK1.indb 15
Anl_GC-WW_6036_SPK1.indb 15
GB
6.3 Electrical connections
•
Connect the appliance to a 230 V ~ 50 Hz
socket-outlet with earthing contact. Minimum
fuse 10 ampere.
•
A built-in thermostat protects the motor from
overloading and blocking. The pump is swit-
ched off automatically by the thermostat if
overheating occurs and is switched on again
automatically after cooling.
6. Operation
•
Install the equipment on a solid and level sur-
face.
•
Fill the pump housing with water via the water
filler screw (5). Filling the intake line accelera-
tes the intake process.
•
Open the discharge line.
•
Connect the mains cable. The intake process
starts automatically;
water can be suctioned in for up to 5 minutes
(maximum suction height).
•
The equipment will shut down when the cut-
out pressure of 3 bar is reached.
•
After a loss of pressure due to water con-
sumption the equipment will cut in again auto-
matically (cut-in pressure approx. 1.5 bar).
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
The equipment is almost completely maintenance
free. In order to ensure a long service life, howe-
ver, we recommend that you regularly check and
care for the product.
Danger!
The equipment must be disconnected from the
power supply (pull the power plug) prior to perfor-
ming any maintenance.
- 15 -
06.04.2017 11:49:49
06.04.2017 11:49:49