Read, understand, and follow all safety information contained in these
instructions prior to installation and use of the AP200 Drinking Water
Filtration System. Retain these instructions for future reference.

Intended use:

The AP200 Drinking Water Filtration System is intended for use in fi ltering potable water
in homes and has not been evaluated for other uses. The system is typically installed
under a sink, and should be installed by qualifi ed professional installers according to
these installation instructions.
EXPLANATION OF SIGNAL WORD CONSEQUENCES
WARNING
C C AUTION
To reduce the risk associated with ingestion of contaminants due to use with water that is
microbiologically unsafe or of unknown quality:
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system.
To reduce the risk associated with a hazardous voltage:
• Do not install near electric wiring or piping which may be in the path of a drilling tool when se-
lecting the position to mount the fi lter bracket.
To reduce the risk associated with property damage due to water leakage:
• Read and follow Use Instructions before installation and use of this system.
• Installation and Use MUST comply with all state and local plumbing codes.
• Protect from freezing. Drain fi lter when temperatures drop below 40°F (4.4°C).
• Do not install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 125
psi, you must install a pressure limiting valve. Contact a plumbing professional if you are uncer-
tain how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer conditions exist you
must install a water hammer arrester. Contact a plumbing professional if you are uncertain how
to check for this condition.
• Install on COLD water lines only. (40-100°F (4.4-37.8°C))
• The disposable fi lter cartridge must be replaced every six months or at the specifi ed service
cycle.
• Do not use a torch or other high temperature sources near fi lter or plastic fi ttings.
• Do not install near water pipes which will be in path of a drilling tool when selecting the position
to mount the bracket.
• Mount fi lter in such a position as to prevent it from being struck by other items used in the area of
installation (waste baskets, etc).
• On plastic fi ttings, never use pipe sealant or pipe dope. Use thread sealing tape only.
• Ensure all tubing and fi ttings are secure and free of leaks.
• Shut off fuel supply to water heater after water is shut off.
• Failure to follow instructions may void warranty.
• Allow a minimum of 7 1/2" (19.5 cm) clear space under fi lter to facilitate cartridge change.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.
• Do not crimp copper tubing.
SAFETY INFORMATION
Indicates a potentially hazardous situation, which, if not avoided, could
result in death or serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may
result in property damage.
WARNING
CAUTION
IMPORTANT NOTES