INCIDENT
8. Salted water in
in service line
9. No brine draw
10. The valve
regenerates
constantly
11. Constant leakage
to the drain
Options
Hot water available only on the 4600 valve:
The use of specific materials allows the valve to work at temperatures higher than 43°C: Up to
82°C for a timeclock version or 65°C for a metered version.
Immediate Regeneration:
As opposed to time clock or metered valves that regenerate at 2 A.M. this option allows the
valve to regenerate immediately after the set capacity is consumed
Fast Regeneration (FR):
This option allows the valve to regenerate in 90 minutes instead of 180 minutes. This valve can
only be fitted with vessels up to 10".
Low water usage piston (L.W.U.):
With this piston, water consumption during regeneration can be reduced.
17
CAUSE
A. Filter and injector blocked
B. Power head not operating proper cycles
C. Foreign elements in brine valve
D. Foreign elements in the brine line
flow control (BLFC)
E. Low water pressure
F. Wrong programming
A. Plugged drain line flow control (DLFC)
B. Plugged filter and injectors
C. Low water pressure
D. Internal valve leak
E. Wrong programming
F. Power head not operating properly
A. Faulty power head
B. Faulty microswitch or wiring loom
C. Defective or badly set cycle cam
A. Foreign elements in the valve
B. Internal valve leak
C. Valve blocked in brine refill or backwash
D. Defective or blocked timer motor
E. Powerhead not operating properly
SOLUTION
A. Clean injector and filter
B. Change power head
C. Change brine valve seat and clean it
D. Clean BLFC
E. Raise inlet pressure to 1,8 bar minimum
F. Check programming and modify if necessary
A. Clean drain line flow control
B. Clean filter and injector, change if necessary
C. Increase inlet pressure to 1,8 bar minimum
D. Change seals, spacers and/or piston assembly
E. Check programming and modify if necessary
F. Change power head
A. Change power head
B. Change microswitch or wiring loom
C. Reposition or change cycle cam
A. Clean valve and check it in the different
regeneration positions
B. Change seals & spacers and/or piston assembly
C. Change seals & spacers and/or piston assembly
D. Change motor and check gear teeth
E. Change power head