Bathtime limit – Maximum permissible bathing time.
Standby limit – Maximum length of time the system may be manually switched on while in standby mode.
Temperature limit – Maximum bathing temperature.
Water pressure – Current water pressure. Default is 5 bar.
Overheating limit – Maximum water temperature before the tank empties automatically.
Filtered temperature – Indicates whether you wish to see the exact thermistor value. Showing the filtered value avoids
fluctuations in the displayed temperature.
Diagnostics
Relay control – Only for Tylö service technicians.
Extra relay control – Only for Tylö service technicians.
System status – Shows current status for water level, water temperature, sauna temperature, electrode value for level
indicator, running time, software/hardware version and product ID.
Heater-net node list – Shows which products are connected to the system.
Error log – Any system errors are logged here.
Factory reset
Enter code 421 to reset the control panel to the factory default settings.
Error messages
Message
"Sauna temperature sensor
failure."
"Fel på temperaturgivaren i
bastun"
"Tank temperature sensor failure."
"Fel på temperaturgivaren i
tanken"
"Electronics in heater overheated"
"Elektroniken i värmaren är
överhettad."
"Lost contact with control panel."
"Tappat kontakten med
manöverpanelen."
"Lost contact with
temperature/humidity sensor."
Tappat kontakten med givaren för
temperatur/fuktighet."
"Tank overheated."
"Tanken överhettad."
"Hardware error. Contact service"
"Hårdvarufel. Kontakta
kundtjänst."
"Power outage. Set time."
"Strömavbrott. Ställ in klockan."
"Lost contact with fragrance
pump."
"Tappat kontakten med
doftpumpen."
 
 
Code
Comments
0x0001
Sensor in sauna room
short-circuited or not
connected.
0x0002
Sensor in tank short-
circuited or not
connected
0x0003
Temperature of circuit
board in control box
higher than 70°C.
0x0006
System restarted
because control box
unable to communicate
with one of control
panels.
0x0007
System restarted
because control box
unable to communicate
with one of sensors.
0x0008
Temperature in tank has
exceeded the limit set by
operator.
0x0009
Real time clock has
stopped working.
0x000a
Real time clock has been
zeroed.
0x000c
System restarted
because control box
unable to communicate
with one of fragrance
pumps.
System behaviour
Action
Current bathing cycle
Check cables and
terminated. New
connections. Test with
bathing cycle cannot
another sensor.
be initiated.
Current bathing cycle
Check cables and
terminated. New
connections. Test with
bathing cycle cannot
another sensor.
be initiated.
Current bathing cycle
Wait until temperature
terminated. New
has fallen to 70°C or
bathing cycle cannot
less.
be initiated until
temperature falls to
70°C or less.
Control box restarts
Restart system. Check
after 60 seconds when
cables/connections.
connection with
Replace control panel.
control panel
interrupted.
Control box restarts
Restart system. Check
after 60 seconds when
cables/connections.
connection with
Replace sensor.
control panel
interrupted.
Tank cycle restarts.
Restart system. Check
pipes from sauna
heater.
Clock and date no
Restart system. If
longer updated.
same error message
appears, replace
circuit board in control
box.
Time and date revert
Set to current time and
to default.
date.
Control box and
Restart system. Check
control panels restart
cables/connections.
after 60 seconds.
Replace fragrance
pump.