Télécharger Imprimer la page

Tylo h2 Mode D'emploi page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
11
10
Figure 6. Basic menu h2
Explanation of symbols:
1.
On/Off
2.
Temperature
3.
Program start time
4.
Settings menu
5.
Status display (figure 7) – Indicates the status of certain functions (see 12, 13, 14, 15 and 16)
6.
Up – One step up in the menu or one step up in the value entered
7.
Lighting – Switches lighting on/off in the sauna/steam room
8.
OK – Confirms selection
9.
Down – One step down in the menu or one step down in the value entered
10. Back – One step back in the menu tree or one step back when entering values
11. Home – Returns you to the basic menu (Figure 6)
12. Indicates that the sauna/steam generator is on
13. Indicates that h2 is programmed to start at some later point in time
14. Indicates that the lighting is on
15. Indicates that the panel is locked
16. Humidity – Indicates approximate water level in tank. Symbol filled = full tank. Symbol half-filled = half tank.
Flashing symbol (unfilled) = tank empty.
17. Humidity
Initial set-up process
When activating h2 for the very first time, it is necessary to program a number of basic settings:
1.
Set the region (Europe, USA, Other). Use the Up and Down arrows and press OK to confirm your selection.
2.
Select language. Use the Up and Down arrows and press OK to confirm your selection.
3.
Set the desired running time (1–12 hours) and press OK to confirm.
4.
Set the current time and press OK to confirm.
5.
Set the current date (YYYY-MM-DD) and press OK to confirm.
Start
To start the sauna heater, move your hand in front of the screen. The screen will then light up. The On/Off symbol will be
highlighted. Press OK. The small On/Off icon will then light up in the status display (5) to indicate that the sauna heater has been
switched on. If the On/Off button (1) is not illuminated, press the Up arrow to step to the right position. To switch off, step to (1) and
press OK.
While the sauna heater is in operation, the current temperature and time will be displayed unless any alterations are made to the
settings.
When the sauna heater is switched off or after the bathing time has elapsed, the heater will switch to drying mode. This means that
the heating elements are allowed to work alone for 20 minutes to dry out the sauna room. This function can be terminated at any
stage by pressing the on/off symbol.
When the sauna heater is switched off, the illumination in the control panel will fade. It can be automatically reactivated by moving
your hand in front of the panel.
Setting the desired bathing temperature
Press the Up or Down arrow to highlight the temperature symbol (2) and press OK. Set the desired temperature using the Up/Down
arrows and then confirm this by pressing OK. When the temperature set is higher than 70°C, priority is given to heating the sauna
room. When the temperature set is lower than 70°C, priority is given to producing steam in the sauna room. It is possible to alter
these priorities in the settings menu.
 