Annovi Reverberi RSV Série Mode D'emploi page 10

Masquer les pouces Voir aussi pour RSV Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions and Parts Manual
Plunger Pumps
Unloader Adjusting
Instructions
Follow these easy steps to adjust the
pressure.
1.
Loosen nut (pos #3) with 10mm
wrench.
2.
Turn brass (pos #4) clockwise until
it stops.
3.
Start pump, watch pressure gauge
and turn (pos #2) using 3mm hex
clockwise until recommended/
rated pressure is obtained. Line
pressure will be approximately
200 psi less then actual head
pressure. DO NOT set line
pressure to rated.
4.
Release trigger and make sure
there is minimal spike (200-300
psi) (Repeat this step two or three
times).
5.
Tighten nut (pos #3) down against
(pos #4).
en 10
RSV Series Pumps
When Quality Matters

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rsv-f25Rsv-f40

Table des Matières