BTL7-A/C/E/G501/504/505-... / BTL7-C/E508/509/512/513-...
BTL7 Configuration Tool
3
Windows and tabs (continued)
3.3
Magnet tab
3.3.1
Number of magnets
► Select the number of magnets used.
U
does not need to be clicked on, clicking an
pdate btl
option field immediately updates the BTL and the graphic.
For the "2 magnets" setting there must be
exactly two magnets on the BTL and two
outputs.
Selecting the "Flexible Magnet Mode" allows for
a flexible number of magnets (1 or 2).
3.3.2
Assignment
Graphical display of the magnets and their output
functions.
Boundary conditions for several magnets
–
The "2 magnets" and "Flexible Magnet Mode" settings
can only be selected if the nominal length is ≥ 90 mm.
–
The distance between two magnets must be ≥ 65 mm.
www.balluff.com
When two magnets are used (only possible with two
outputs) the output assignments are distinguished by color.
By default, the magnet which is closest to the start point is
assigned to Output 1, and the magnet closest to the end
point to Output 2.
Swap assignment
Reverses the assignment of magnets to outputs.
Exception: If the "Differential position" function is set for
both outputs, the assignments cannot be reversed.
If "1 magnet" is selected, both outputs are
assigned to this magnet. The outputs are not
distinguished by color and the assignments
cannot be reversed.
english